Check Operation; Electronic Ignition System - Whirlpool 8273166 Installation Instructions Manual

30" freestanding sealed burner gas range with standard clean oven
Table of Contents

Advertisement

Check operation

E

Electronic ignition system

Cooktop and oven burners use electronic
ignitors in place of standing pilots. When a
cooktop control knob is turned to the
"LIGHT" position, the system creates a
spark to light the burner. This sparking
continues until the control knob is turned to
the desired setting.
When the oven control is turned to the
desired setting, a hot surface ignitor heats to
a bright orange and ignites the gas. No
sparking occurs and the glow bar remains
on while the burner operates.
Check operation of cooktop
15.
Push in and turn each surface unit
control knob to "LIGHT" position. The flame
should light within 4 seconds. Turn control
knob to "HIGH" position after burner lights.
Check each cooktop burner for proper flame.
The small inner cone should have
a very distinct blue flame 1/4" to
1/2" long. The outer cone is not as
distinct as the inner cone.
Note: the cooktop burners have
been set at the factory for proper
operation. No adjustment is
required. If the burner does not have the
proper flame, call your dealer.
Page 6
Check operation of oven burner
16.
Open broiler drawer to observe
oven burner operation.
OFF
PUSH TO
TURN
200
250
300
450
350
400
Push in and turn the oven selector control
knob to "350˚F." The oven burner should light
in 50-60 seconds; this delay is normal. The
oven valve requires a certain time before it will
open and allow gas to flow.
To avoid damaging the hot surface ignitor,
do Not insert any object into the openings of
the protective shield that surrounds the
ignitor or clean that area.
17.
Check the oven burner
for proper flame. The flame should
be 1/2" long, with inner cone of
bluish-green, and outer mantle of
dark blue, and should be clean and soft in
character. No yellow tips, blowing or lifting of
flame should occur. If burner does not light,
check that the regulator shutoff valve is in the
"on" position (see Step 11).
regulator
shutoff valve
air shutter
and screw
If oven flame needs adjusting:
Locate the air shutter next to the pressure
regulator. Loosen screw and adjust the air
shutter until the proper flame appears. Tighten
screw.
18.
Turn the control knob to "OFF".
Check operation of broil burner
19.
same burner.
BROIL
550
500
Push in and turn the oven selector control knob
to "BROIL." The broil burner should light in 50-
60 seconds; this delay is normal. The oven
valve requires a certain time before it will open
and allow gas to flow.
20.
operating.
21.
oven control knob to "OFF".
You have just finished installing
your new range. To get the most
efficient use from your range, read
your Use & Care Guide. Keep
Installation Instructions and Guide
close to range for easy reference. The
instructions will make installing the
range in another home as easy
as the first installation.
Broil burner and oven burner are the
OFF
PUSH TO
TURN
BROIL
200
550
250
500
300
450
350
400
Check that the broil burner is
Close the broiler drawer. Turn the

Advertisement