VI. MAINTENANCE AND CLEANING INSTRUCTIONS
Ensure all components, fasteners and thumbscrews are securely in place after
any maintenance or cleaning is done to the equipment.

1. PREPARING THE ICEMAKER FOR LONG STORAGE

When shutting off the icemaker for an extended time, drain out all water from
the water tank and remove the ice from the Storage Bin. The Storage Bin
should be cleaned and dried. Drain the icemaker to prevent damage to the
water supply line at sub-freezing temperatures, using air or carbon dioxide.
Shut off the icemaker until the proper ambient temperature is resumed.
• When the icemaker is not used for two or three days, it is sufficient to only move the
Control Switch to the "OFF" position, unless the icemaker will be at sub-freezing
temperatures.
[1] On water-cooled model only, first remove the water from the water-cooled condenser:
1) Remove the Front Panel.
2) Move the Control Switch, on the Control Box, to the "OFF" position.
3) Wait 3 minutes.
4) Move the Control Switch to the "ICE" position.
5) Allow 5 minutes for the icemaker to fill with water and the Water Pump to start
operating.
6) Close the Water-cooled Condenser Water Supply Line Shut-off Valve.
7) Open the Drain Valve for the water-cooled condenser water supply line.
8) Allow the line to drain by gravity.
9) Attach compressed air or carbon dioxide supply to the Condenser Water Line Drain
Valve.
10) Quickly blow the water-cooled Condenser out, using compressed air or carbon
dioxide until water stops coming out.