INSTALLATION Continued
All burners are equipped with constant-burning pilots. These
should be manually lighted immediately after the gas is
turned on and the system is checked for leaks. An adjustment
screw for each pilot is located on the gas manifold and can
be accessed through openings in the valve panel between
the valve knobs.

Testing and Adjustments

Part # Rev 3 1844033 (02/22/08)
Check all gas connections for leaks using a soapy solution
before lighting any pilots. DO NOT USE OPEN FLAME
TO CHECK FOR LEAKS! Putting open flame beside a new
connection is not only dangerous, but will often miss small
leaks that a soapy solution would find.
All U.S. Range appliances are adjusted and tested before
leaving the factory, effectively matching them to sea
level conditions. Adjustments and calibrations to assure
proper operation may be necessary on installation to meet
local conditions, low gas pressure, differences in altitude;
variations in gas characteristics, to correct possible problems
caused by rough handling or vibration during shipment, and
are to be performed only by qualified service personnel.
These adjustments are the responsibility of the customer,
installer and/or dealer and are not covered by the U.S. Range
warranty.