DIMENSIONS AND SPECIFICATIONS

Model #
Width (A)
IRCMA-24
24(610)
IRCMA-36
36(914)
IRCMA-48
48(1219)
IRCMA-60
60(1524)
IRCMA-72
72(1829)
* Natural and Propane Gas
Manifold Operating Pressure
All Models
Natural Gas
"WC
Mbar
5
12.5
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
6 1/2"
(165 mm)
Part # 1382697 Rev. 1 (10/18/11)
Dimensions: In. (mm)
Depth
17-5/8(447)
17-5/8(447)
17-5/8(447)
17-5/8(447)
17-5/8(447)
Propane
"WC
Mbar
10
25
A
No. of
Burners
Height
18-3/4(476)
1
18-3/4(476)
1
18-3/4(476)
2
18-3/4(476)
2
18-3/4(476)
3
Type of Construction Installation
Combustible
Rear
Sides
Counter installations base must be a non-combustible.
1 1/4" (32 mm) ANGLE IRON BRACKET FOR WALL MOUNT
2 5/8"
(67 mm)
3/4" N.P.T GAS INLET
10 "
(254 mm)
18 3/4"
(476 mm)
Weight
Total BTU*
Lb/Kg
20,000
145/66
30,000
185/84
40,000
230/105
50,000
265/120
60,000
300/136
Minimum Clearance
Non-Combustible
3" (76mm)
Rear
6" (152mm)
Sides
17 5/8"
(448 mm)
Cu Ft
9
13
17
21
25
0"
0"
20 "
(508 mm)