Maintenance/Service; Internal Water Level; Draining Water; Cleaning The Air Filter - Friedrich ZoneAir P-09 Installation & Operation Manual

Table of Contents

Advertisement

Condensation Handling

Your ZoneAire
Portable Air Conditioner is designed to evapo-
®
rate the condensation removed from the interior space through
the exhaust hose. Under certain conditions it is possible that
the unit will not evaporate 100% of the removed moisture.
The unit is designed with a built-in reservoir and pump to ac-
cumulate excess condensate and help dispose of it.

Internal Water Level

1. Under any mode if the water level is in the "low" area the unit
will function normally.
2. If the water level is in the "normal" area the unit will continue
to function normally with the internal recirculation pump run-
ning to evaporate the water. You may hear the pump run at
times.
3. If the water level is in the "high" area the unit will function
normally and the water pump will work for 10 minutes. After
that, if the water level returns to the "low" or "normal" level
the unit will function normally. If after running 10 minutes,
the water level is still in the "high" area the machine will turn
off and the WATER FULL lamp on the control panel will il-
luminate. The LCD window indicates failure code E5.
water tank
water
Maintenance /Service
!
WARNING
• Disconnect the power before cleaning.
• Make sure there is no power to the unit before
beginning to maintain or repair the unit in or-
der to prevent accidents caused by electrical
shock.

Cleaning the air filter

If the air fi lter is blocked with a lot of dust, the air fl ow volume
will be reduced. Clean the fi lter once every two weeks.
Open and clean the air fi lter:
1. Pull the fi lter out as shown in the drawing.
2. Take out the air fi lter from the fi lter cover.
3. Wash the air fi lter by immersing it gently into warm (about
40°C or 104°F) water with a neutral detergent or vacuum the
fi lter clean.
4. Rinse the fi lter and dry it thoroughly in a shaded place.
5. Install the air fi lter back to its original place.

Draining Water

The water can be drained from the unit either by removing the
base stopper and letting the water drain by gravity. Or the con-
densate pump hose may be used to direct the condensate to a
drain location like a sink.
1. When the WATER FULL lamp is on unplug the unit and
move the unit to a suitable location for draining the conden-
sation.
2. If using the gravity drain method ensure that the base stop-
per is located above a suitable area for draining the conden-
sate and remove the stopper. Re-install the stopper once all
water has drained.
If using the condensate removal pump ensure that the conden-
sate pump hose is located in a proper area for drainage. Re-
store power to the unit and press both the TIMER and SWING
buttons simultaneously and the pump will begin to run.
3. Return the unit to the original location and restore power
and duct connections.
4. The WATER FULL indicator should be off and the unit will
return to normal operating mode.
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zoneaire p-09

Table of Contents