Heatilator Fi36S Installation & Operating Instructions Manual
Heatilator Fi36S Installation & Operating Instructions Manual

Heatilator Fi36S Installation & Operating Instructions Manual

Imperial gas logs

Advertisement

INSTALLATION & OPERATING INSTRUCTIONS
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional information, consult a qualifi ed installer, service agency or
the gas supplier.
11/12
IMPERIAL GAS LOGS
Fi36S
Fi36SL
Fi42S
Fi42SL
FOR RESIDENTIAL USE
WARNING!
33734 Rev K
Fi36M
Fi36ML
Fi42M
Fi42ML
WARNING:
If the information in this manual
is not followed exactly, a fi re or explosion may
result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any other
appliance.
— What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fi re
department.
— Installation and service must be performed by a
qualifi ed installer, service agency or the gas sup-
plier.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator Fi36S

  • Page 1 INSTALLATION & OPERATING INSTRUCTIONS IMPERIAL GAS LOGS Fi36S Fi36SL Fi36M Fi36ML Fi42S Fi42SL Fi42M Fi42ML FOR RESIDENTIAL USE WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier. Table of Contents Listings and Code Approvals ............................3 Description of the Imperial Gas Log Set..........................3 C. Important Information ..............................5 D.
  • Page 3: Listings And Code Approvals

    A. Listings and Code Approvals The Imperial Series Gas Log Set has been tested and listed in the U.S. in accordance with ANSI Z21.60-1996 (Gas Log Set). In Canada the Imperial Series Gas Log Set has been tested and approved in accordance with CGA 2.26-M96. It has been listed by Underwriters Laboratories Inc.
  • Page 4 These gas log sets are available with different valve systems. The Fi36S, Fi36SL, Fi42S and Fi42SL sets use a separate regulator and valve system, and the Fi36M, Fi36ML, Fi42M and Fi42ML sets use a combination control with an intermit- tent pilot. Both valve systems are available in natural or propane gas. Only the “M” Series can be used with an optional remote control (RC-BATT-HTL).
  • Page 5: Important Information

    C. Important Information Installer: Please leave these instructions with the owner. Owner: Please retain these instructions for future reference. Important: Read these instructions carefully before making installation. • This appliance must be installed only in a solid-fuel burning (woodburning) fi replace with a working fl ue and constructed of noncombustible materials.
  • Page 6: Step-By-Step Installation

    D. Step-by-Step Installation 1. Unpack the Log Set b. Remove the four screws that secure the top pan to Carefully remove all parts from the shipping container. the base of the appliance. See Figure 4. Your set includes four fi ber logs, a burner assembly, the grate assembly, fi...
  • Page 7 f. Bleed the gas line to extract any air that may have been trapped inside the pipe. All connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off the solution when done leak testing.
  • Page 8 7. Place the Logs a. Rear Log c. Top Right Log The rear log is supplied with locating slots in the The top right log is supplied with locating slots in base of the log. Locate the rear log over the locating the base of the log.
  • Page 9 8. Intermittent Pilot Ignition a. Appliance Requirements: This appliance does not require 110VAC supply for operation. 1) A wiring diagram is shown in Figure 13. A battery pack is supplied with the appliance. This appliance requires the use of two D-cell batteries (not supplied with the appliance) for operation. 2) In the event of a power outage, the appliance will continue to operate if batteries are installed in the battery pack.
  • Page 10: Operating Instructions For The "M" Series

    E. Operating Instructions for the “M” Series FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has an intermittent pilot. When Do not use this appliance if any part has been lighting the pilot, follow these instructions under water.
  • Page 11: Operating Instructions For The "S" Series

    F. Operating Instructions for the “S” Series FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lit by Use only your hand to push in or turn the gas control hand.
  • Page 12: Glass Doors

    G. Glass Doors If your fi replace is equipped with a glass door, the glass doors should be in the full open position when the appliance is operating. Operating the fi replace with the glass doors closed will block the radiant heat output of the fi replace and may cause incomplete combustion of the natural or propane gas fuel.
  • Page 13: Important Safeguards

    2. Possible Cures a. The damper needs to be opened further. b. The fi replace opening needs to be reduced by adding a drop panel across the top under the lintel. c. The air supply from outdoors needs to be increased. Open the outside air kit if the fi replace is so equipped, or crack open a door or window.
  • Page 14 FI36M, FI36ML Service Parts Beginning Manufacturing Date: N/A Imperial 36” Gas Log Set Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 11/12 33734 Rev K 11/12...
  • Page 15 FI36M, FI36ML Service Parts Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 16 FI36S, FI36SL Service Parts Beginning Manufacturing Date: Nov 2000 Imperial 36” Gas Log set Ending Manufacturing Date: Nov 2006 Log Set Assembly 12 13 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for Stocked your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 17 FI42M, FI42ML Service Parts Beginning Manufacturing Date: N/A Imperial 42” Gas Log set Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 11/12 33734 Rev K 11/12...
  • Page 18 FI42M, FI42ML Service Parts Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 19 FI42S, FI42SL Service Parts Beginning Manufacturing Date: Nov 2000 Imperial 42”Gas Log set Ending Manufacturing Date: Nov 2006 Log Set Assembly 12 13 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for Stocked your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 20: Troubleshooting - "M" Series

    N. Troubleshooting - “M” Series With proper installation and maintenance, your new decorative gas appliance should provide years of trouble-free service. If you do experience a problem, refer to the troubleshooting guide below. This guide will assist you or a qualifi ed service technician in the diagnosis of problems and the corrective action to be taken.
  • Page 21: Troubleshooting - "S" Series

    O. TROUBLESHOOTING - “S” SERIES Symptoms Possible Causes Corrective Action 1 Match will not light pilot. a. Main gas shutoff valve closed. Make sure that the shutoff valve located on the incoming gas line is open. b. Air in the gas line. Light a match.
  • Page 22: Accessory Parts (For "M" Series Only)

    P. Accessory Parts (For “M” Series Only) The following accessory parts can be obtained from your dealer. The wireless remote control switch is supplied with installation instructions packaged with them. Should you need additional information please contact your dealer for more information or visit: www.hpba.org/staysafe. Remote Control RC-BATT-HTL 33734 Rev K...
  • Page 23: Warranty

    Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 24 WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 33734 Rev K 11/12...

This manual is also suitable for:

Fi36mFi36mlFi42sFi42slFi42mFi42ml ... Show all

Table of Contents