The spiral chamber is basically self-cleaning. However, if there is a draft problem and you have been burning wood for a
long time with little demand, the spiral chamber will need to be cleaned. To clean the spiral chamber, remove the stovepipe
and scrape any creosote or debris from the top and front of the chamber. The rear of the chamber should not have much
accumulation. If it does, clean it out.
nOTE: 1/4" to 1/2" of creosote in the spiral chamber is normal.
The pipes inside the firebox will accumulate creosote if the demand for heat is too low, when burning wood. 1/8" to 1/4"
of creosote is normal on the pipes and firebox walls. If more creosote has accumulated, it should be scraped off of these
surfaces.
nOTE: Creosote in the firebox can be burned off by burning coal for a few days.
The fire bricks may become cracked during the course of normal operation. a cracked brick that is still in place, is still doing
its job, and need not be replaced immediately. If a brick is broken, and has fallen out of place, it should be replaced before
any further burning occurs. The firebricks used in the Trident Boiler are available for replacement from your Harman® dealer.
Gaskets on the doors are there to regulate air to the firebox. If a gasket is failing, you'll notice difficulty in controlling the fire.
Inspect the gaskets regularly, and replace with Harman® supplied material only.

Specifications

Heating Capacity (square feet)
approximate BTU per hour (wood or coal)
aMP Rating
Water Capacity (Us Gallon)
Weight
Hydro-Pressure Tested
firebox Dimensions (inches)
Recommended log length (inches)
Door Opening size (inches)
Overall Dimensions (inches)
flue size (diameter)
flue Height (top of flue)
number Of Grates (10 lbs. Each)
Type Of fuel
Water Inlet and Outlet size
automatic Draft Control
aquastat
Temperature / Pressure Gauge
asME Pressure Relief Valve
ash Pan With Handle
Domestic Hot Water Coil (optional)
approximate BTU per hour (electric option)
Kilowatt Rating (electric option)
13

Maintenance

SF-160
2200 Max.
90,000
40
25
640 lbs
Yes
16W x 22l x 19H
19
11 x 13
23W x 23.5l x 45H
6 inch
37.5 inches
4
Coal / Wood
1.25 nPT
Yes
Yes
Yes
Yes
Yes
4 GPM
30,000
9
SF-260
3200 Max.
130,000
40
32
780 lbs
Yes
18W x 26l x 20H
23
13 x 13
26W x 27.5l x 45.5H
26W x 31.5l x 51.5H
7 inch
38.75 inches
5
Coal / Wood
1.25 nPT
Yes
Yes
Yes
Yes
Yes
4 GPM
30,000
9
SF-360
4500 Max.
180,000
40
42
925 lbs
Yes
18W x 30l x 25H
27
13 x 13
7 inch
44 inches
6
Coal / Wood
1.25 nPT
Yes
Yes
Yes
Yes
Yes
4 GPM
30,000
9
3-90-70742R11_05/13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trident sf260Trident sf360

Table of Contents