USING MERIDIAN ROOM
CORRECTION
The next page allows you to specify which input card and analogue input
you are going to use for the microphone or Sound Pressure Level meter,
and the sensitivity of the input:
• Select the appropriate card and input.
• Specify the input sensitivity.
• Click the Next button to continue.
• Connect the SPL meter or microphone to the input you specifi ed, switch
on the SPL meter and position it at the listening positioning.
When using an SPL meter the C weighting must be used, and the 90dB
range is recommended, unless the loudspeakers measured less than 75dB
SPL during the calibration in which case the 80dB range is recommended.
• Click the Test mic button to run a test to check that the microphone is
connected correctly:
104