Mantels And Surrounds; Wiring - Montigo L52DF Installation & Maintenance Manual

Flush indoor gas fireplace
Table of Contents

Advertisement

L52DF Flush Indoor Gas Fireplace
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Painting:
Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and apply
a quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.
Surround Heat Shield
Included with the L52DF Gas fireplace, is a heat shield fabricated from
galvanized steel. The kit comes with three (3) pieces as shown below.
This shield is to protect all adjacent combustible mantels and mouldings
from excessive heat radiated by the cabinet of the fireplace. This shield
must be installed as shown in Figure 24a.
1). Top shield fastened as shown. Wide flange face up, shallow flange
toward inside of room, nailed or screwed flush with framing.
2). Side shield's fastened as shown. Wide flanges face out, shallow flange
toward inside of room, nailed or screwed flush with framing.
Top shield
Side shield
Figure 24a. Combustible surround Shield, (three (3-pcs).
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
Page 14
Installation
Framing
1/2
Fasteners
1/2
3-Per Shield
Framing
4
Fasteners
3-Per Shield
Side shield
L52DF
Drywall/Sheetrock
Header
Figure 25. Combustible surrounds.

Wiring

Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Gas Control
Connector
Fan Plug
Receptacle
Gnd Screw
Wall Switch
Figure 26.
Wiring for the L52DF-I with Honeywell gas control and pilot.
WARNING!
Use Montigo Part No. #HSIT07 Water-tight electrical box, or
equivilent equipment. Ensure the box is installed in a dry location
and avoid any moisture. Figure 26a.
If you install 110V Wire, ensure you use Ground fault breakers.
Also avoid any moisture near or around the 110V Circuit.
f i r e f e a t u r e
Non-Combustible
Facing Material
6"
L52DF-I
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Junction Box
115VAC
24VAC
40 VA
Transformer
Part No. XG0185 - 092109
3"
Black
White
Green