Section 3-3-2: Venting Components - Montigo H42DF Installation & Maintenance Manual

Indoor residential gas fireplace
Table of Contents

Advertisement

H*42DF Indoor Gas Fireplace
Section 3-3-2:
VEnTInG COMPOnEnTS
The following components and associated Montigo part numbers for
installation of a roof or wall mounted termination. Use only Montigo
Vent Components. Use of non-Montigo parts will VOID the warranty
and may impede operation of the fireplace.
a - Termination
B - Frame Kits
C - Flex Sections
D - Rigid Sections
E - Elbows
F - Support Ring & Plate
G - Firestop
H - Roof Flashing
I - Heat Shield
J - Heat Guard
Page 16
Installation
PTO-4
(3" Length)
PTO-4F
(3" Length)
PVTK-1
MSR
(Stucco Frame)
MOSR
(Stucco Frame)
BSR-4
(4" Brick Frame)
BSR-6
(6" Brick Frame)
PFL - 1
(12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2
(24" f/f Section)
PFL - 3
(36" f/f Section)
PFL - 4
(48" f/f Section)
PFL - 6
(72" f/f Section)
PXT - 5
(5" f/f Section)
PXT - 10 (10" f/f Section)
PXT - 20 (20" f/f Section)
PEXT - 1 (12" f/m Section)
PEXT - 2 (24" f/m Section)
PEXT - 3 (36" f/m Section)
PEXT - 4 (48" f/m Section)
PEXT - 6 (72" f/m Section)
PEL-90MM (m/m 90º Elbow)
PEL-90FF ( f/f 90º Elbow)
PEL-90FM ( f/m 90º Elbow)
PEL-45FM ( f/m 45º Elbow)
PSPXT-8
FS-8
PRF-7
(1/12 - 7/12 pt.)
PRF-12
(7/12 - 12/12 pt.)
RHS101
PTKOG
Connection and installation of the vent components should
adhere to the following guidelines:
Use any combination of rigid and flex pipe as required and in
any orientation (Male connectors can face in any direction).
Flex sections may be stretched up to 50% of their total length
(e.g. a 24" section maybe stretched to 36").
Connect all vent sections using a minimum of three sheet metal
screws on the outer pipe flue.
Ensure the pipe ends male to female slide in a minimum of 1
1/2" of overlap.
Ensure all runs are supported with a minimum of 3 supports
per 10' of venting.
When hanging/ supporting venting, ensure that 1" clearance
is maintained on sides and bottom of vent runs and 2" above
horizontal vent runs to any combustible material.
Rigid pipe may be cut less than half way from the female end only.
Ensure when cutting sections of rigid pipe to maintain integrity
of internal supports.
Place the springs, supplied with the pipe kit, between the outer
and inner pipes to keep the pipes separate and avoid any
possible hot spots.
Montigo recommends the use of a flex section for the final pipe
connected directly to the fireplace offering greater flexibility of
installation and absorption of movement.
Firestops must be installed as required by National & local codes .
Montigo recommends that all exterior corners and joints be sealed
with exterior caulking. However, we encourage you to consult
your Building Envelope Engineer or Waterproofing Consultant
for further recommendations.
IMPORTanT:
Please Refer to your Building Envelope Engineer
or waterproofing Consultant for a review of aLL
penetrations through exterior walls or the roof.