Fujitsu Halcyon Operating Manual
Fujitsu Halcyon Operating Manual

Fujitsu Halcyon Operating Manual

Concealed ceiling type
Hide thumbs Also See for Halcyon:

Advertisement

Quick Links

AIR CONDITIONER
CONCEALED CEILING TYPE
KEEP THIS MANUAL FOR FUTURE REFERENCE
CONSERVEZ CE MODE D'EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
FUJITSU GENERAL LIMITED
OM_9373117063-en.indd 1
OM_9373117063-en.indd 1

OPERATING MANUAL

MODE D'EMPLOI
MANUAL DE FUNCIONAMIENTO
SU MO TU WE TH FR SA
AM
PM
3 6 9 12 15 18 21
P/N9373117063
9/10/07 5:16:06 PM
9/10/07 5:16:06 PM

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu Halcyon

  • Page 1: Operating Manual

    3 6 9 12 15 18 21 KEEP THIS MANUAL FOR FUTURE REFERENCE CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO FUJITSU GENERAL LIMITED P/N9373117063 OM_9373117063-en.indd 1 OM_9373117063-en.indd 1...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ..........1 TEMPERATURE SET BACK TIMER ........ 7 NAME OF PARTS ............2 SELF-DIAGNOSIS ............8 PREPARATORY OPERATION .......... 2 OPERATING TIPS ............8 OPERATION ..............3 CARE AND MAINTENANCE ......... 11 ON/OFF TIMER ..............4 TROUBLESHOOTING ........... 12 WEEKLY TIMER ...............
  • Page 3: Name Of Parts

    NAME OF PARTS 1 Start/Stop Button Display 2 Set Temperature Button 3 Master Control Button SU MO TU WE TH FR SA 4 Fan Control Button 3 6 9 12 15 18 21 5 THERMO SENSOR Button 6 ENERGY SAVE Button 7 Timer Mode (CLOCK ADJUST) Button CLOCK ADJUST DAY OFF...
  • Page 4: Operation

    OPERATION Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle). To start/stop operation Press the START/STOP button. Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit To set the operation mode Operation mode setting Press the MASTER CONTROL button to set the operation mode.
  • Page 5: On/Off Timer

    OPERATION Room temperature sensor selection THERMO SENSOR Indoor unit Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller. When the thermo sensor display appears, the room temperature is detected at the remote controller.
  • Page 6: Weekly Timer

    WEEKLY TIMER Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle). To set the WEEKLY timer SU MO TU WE TH FR SA CLOCK ADJUST 3 6 9 12 15 18 21 Press the TIMER MODE button to select the weekly timer. Press the SET button for 2 seconds or more.
  • Page 7 WEEKLY TIMER To start/cancel the WEEKLY timer operation To start To cancel SU MO TU WE TH FR SA DELETE CLOCK ADJUST 3 6 9 12 15 18 21 • Press the DELETE button to When the weekly timer is selected, the 3 6 9 12 15 18 21 cancel the timer mode.
  • Page 8: Temperature Set Back Timer

    TEMPERATURE SET BACK TIMER Instructions related to heating are applicable to “HEAT & COOL MODEL” (Reverse Cycle). To set the temperature SET BACK timer SET BACK SU MO TU WE TH FR SA If there is no existing SET BACK tempera- ture setting, “- -”...
  • Page 9: Self-Diagnosis

    SELF-DIAGNOSIS When the error indication “E:EE” is displayed, inspection of the air conditioning system is necessary. Please consult authorized service personnel. (1) Stop the air conditioner operation. Faulty unit number (remote controller address) Error code SU MO TU WE TH FR SA SU MO TU WE TH FR SA ex.
  • Page 10 OPERATING TIPS Energy save Hot start (for heating) • The energy conservation mode (ENERGY SAVE) raises the The indoor unit prevents cold drafts when heating operation set temperature slightly in the cooling mode and lowers begins. the set temperature in the heating mode to economically The indoor unit fan will not operate or it will operate at a control the operation of the unit.
  • Page 11 OPERATING TIPS Multi-type Air conditioner This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.
  • Page 12: Care And Maintenance

    CARE AND MAINTENANCE CAUTION! Before cleaning the unit, be sure to stop the unit and power supply. (Turn off the electrical breaker) Cleaning the air fi lter If dirt is allowed to collect in the air fi lter, the airfl ow will be reduced, leading to reduced performance, and increased operation noise.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). WARNING! In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
  • Page 14 TROUBLESHOOTING Symptom Items to check See Page CHECK ONCE Doesn’t operate at all: Has there been a power failure? — MORE Has a fuse blown out, or a circuit breaker been tripped? Is the timer operating? 5 to 7 Poor Cooling (or Heating) Is the air fi...

Table of Contents