Trane 4TTR2042A1000A Use And Care Manual page 21

1 1/2-5 tons

Advertisement

Performance
Data
Cooling
4TI'R2024A! WI1H TWE036C14 AT 900 CFM
O.D.
I.D.
TOT
SENS.CAP. AT ENTERINGD.B.TEMP
TOTAL
D.B.
W,B.
CAP.
72
75
78
60
KW
59
21,4
201
21.8"
228*
23,4"
2.09
85
63
23,2
16,7
193
219
23.4'
2.13
67
25.1
13,0
156
18.2
20.0
216
59
20.8
198
21 4"
22.3'
22,9*
227
95
63
22.7
16.6
191
21.7
22.9*
231
67
24.6
128
15.4
180
19.7
235
63
21.0
157
18.3
210
21.6'
243
105
67
22.8
12.0
14,7
17,3
19.0
247
71
24.7
8.3
109
13.5
15.3
2,52
63
19,3
15.0
170
19,5'
20,2*
254
115
67
21,0
113
139
16,6
18,3
259
71
22.6
76
102
128
14.6
2,64
CORRECTION FACTORS- OTHERAIRFLOWS(MULTIPLYORADO AS INDICATED)
AIRFLOW
775
1025
AIRFLOW
775
1025
TOTAl.CAP
X0.98
X1 01
SEN8. CAP
X094
X1 06
41TR2024A1 WITH TXNTXC018C4/D4 AT 700 CFM
O,D.
I,O,
TOT
SENS. CAP.AT ENTERINGD.B.TEMP
TOTAL
D.B,
W.B.
CAP,
72
75
78
80
KW
59
19rl
164
182
195"
20.1'
1,94
85
63
209
141
159
176
19'0
199
67
22.7
115
133
15.2
!64
291
59
18.7
16'2
180
19.2"
19.8"
212
95
63
20.5
139
15.6
176
18,9
216
67
22.3
11.3
13.2
151
16.3
229
63
18.9
13.2
151
16,9
18.1
2.29
105
67
20,7
10,6
12,5
14'3
15.6
2'33
71
22.5
8'0
9'8
11.7
12.9
2.3?
63
17.4
12,5
14,3
16'2
17'4"
2,41
113
67
19.1
9.9
11.8
13.6
149
246
71
20.8
7.3
9.1
1!.0
12'2
250
CORRECTIONFACTORS" OTHERAIRFLOWS(MULTIPLYOR ADDAS INDICATED)
AIRFLOW
600
800
AIRFLOW
600
800
TOTALCAP
X0.98
X1.02
8ENS. CAP
X0,94
X1,05
4TrR2624A1 WITH TXA/TXC024C4/D4 AT 800 CFM
O.D.
LD,
TOT
GENS.CAP. AT ENTERINGD.B. TEMP
TOTAL
D.B.
W.B.
CAP.
72
75
78
80
59
19.3
175
196
20,6*
21,2'
2.01
83
63
21.6
14.8
17.0
19.1
20,5
2.03
67
23.5
11.8
14.0
16.1
17.5
2,03
59
19.4
17.3
19.4"
20.2'
20.8"
219
95
63
21.3
14.0
16.8
18.9
20.3
2,23
67
23.0
11.7
13.8
15,9
17.3
2,27
63
19.6
13.9
16.0
18,2
19.6
2,35
105
67
21.3
10.9
131
15.2
16.6
239
71
23.1
7.9
10,0
12.1
13.5
2.44
63
18,0
13.2
16.3
17.5
18.3"
2.46
115
67
196
10.2
12.4
14,5
15,9
2.51
71
21.3
72
9.3
11,4
12,8
2,55
CORRECTIONFACTORS- OTHER AIRFLOWS(MULTIPLYOR ADDAS INDICATED)
AIRFLOW
700
900
AIRFLOW
700
900
TOTALCAP
X093
X1,01
SEN8 CAP
X0.95
X1,05
4"n'R2024A1 WITH TXAJTXC_5C4/D4 AT 800 CFM
O.O.
I.D,
TOT
SENS. CAP.AT ENTERINGO.B. TEMP
TOTAL
D.B.
W.B,
CAP,
72
75
78
80
KW
59
20.8
184
207
2!.7'
22.3*
2,04
65
63
227
155
178
20.9
21.6
2.07
67
245
123
145
168
18.3
2.11
59
203
181
26 9"
21 2"
218"
2.22
95
63
221
15.2
17.5
198
21,3
2.20
67
240
120
143
166
181
2.30
63
20.4
14.5
169
191
20,5*
2,37
105
97
22,2
11,3
136
159
17.4
241
71
241
8.0
103
12.6
14.1
246
63
187
138
16.0
18.3
19.1"
2.46
115
67
20,4
10,6
129
15.1
16.7
2.53
71
22.2
7.3
96
11.9
13.4
2.58
CORRECTIONFACTORS- OTHER AIRFLOWS(MULTIPLYORADD AS INDICATED)
AIRFLOW
700
900
AIRFLOW
700
900
TOTAL CAP
×098
Xl 01
SEN8, CAP
X0,94
X1.05
41-FR2024A1 WITH "rX/VTXC030C4/D4 AT 960 CFM
O.D.
I.D.
TOT
SENS.CAP. AT ENTERINGD.B.TEMP
TOTAL
O.D.
W.B.
CAP.
72
75
78
80
KW
69
21.5
19.7
21.7"
226*
23.2*
2,11
85
63
233
165
!90
214
231
214
67
252
130
154
17.9
19,6
2,18
59
20.8
193
212"
22.1"
22.7*
2,28
95
63
227
162
18.7
21,1
22.7'
2.32
67
246
12,7
152
176
19.3
2.37
63
209
15.4
17,9
20,4
21.3°
2.44
105
67
228
12.0
144
169
18,5
2,48
71
247
8.4
10.9
133
15.0
2,53
63
192
147
171
193"
19,9"
2,55
119
67
20,9
11,2
137
16.1
17.3
2.60
71
22.7
77
101
126
14.2
2.65
CORRECTIONFACTORS- OTHERAIRFLOWS(MULTIPLY OR ADDAS INDICATED)
AIRFLOW
775
1025
AIRFLOW
775
1025
TOTALCAP
X096
X1 01
SENS,CAP
X0.94
X1.06
4TTR2024A1 WI11_ TXA/TXC031C4/D4 AT 900 CFM
O.D.
LD,
TOT
SENS. CAP.AT ENTERINGD.B.TEMP
TOTAL
D.B.
W.B.
CAP.
72
75
76
80
KW
59
217
19.9
22.0"
22.9*
23.5'
2,11
85
63
235
16.6
19.2
218
235
215
67
254
12,9
15,5
181
19.8
2,18
59
21.0
19.6
215"
22.4*
23.0*
2.29
95
63
22,9
16,3
18,9
21.5
23.0"
2,33
67
24.8
126
152
17.8
19.5
2,37
63
21.1
15.5
18.1
20.7
21.5"
2.44
105
67
229
11.9
14.5
17.1
18.3
2.49
71
24.8
8.1
10.7
13.3
15.1
2.53
63
193
14.8
17.4
19.5'
201"
2.55
115
67
211
111
137
163
160
2.60
71
22.9
7,4
!00
12 6
143
265
CORRECTIONFACTORS- OTHER NRFLOWS (MULTIPLYOR ADDAS INDICATED)
AIRFLOW
775
1025
AIRFLOW
775
1025
TOTALCAP
X098
X1.01
SENS,CPP
X094
X106
NOTE:ALLTABLESABOVEARE ATARI RATING CONDITIONS RATEDWITH 25 FEETOF REFRrGERANTLINES
• DRY COILCOND_TtON(TOTALCi_PACITY = SENSIBLE C/_PACITY)
TOTAL CAPACITY,COMP KWAND/_PP DEWP7 AREVALIDONLY FOF_ WET COIL ALL TEMPERATURESIN DEGF_EES F
22-1728-01-1201
(EN)
21