General Information - Trane DCY060F1 User's Information Manual

Single package dual fuel heat pump convertible 2-5 ton 12 seer
Table of Contents

Advertisement

GENERAL INFORMATION,,
OVERVIEW
Your combination
dual fuel heat pump unit is designed to
comfort condition all year long with safe, efficient, trouble-
free operation. It is important that you understand how to
operate and maintain you r unit to keep it operating safely and
efficiently. This manual will acquaint you with these impor-
tant procedures. Familiarize yourself with this manual and
store it in a convenient
location for future reference.
Any additions, changes, or conversions required in order for
the unit to satisfactorily
meet the application needs, should
be made by a qualified product distributor or local service
dealer, using factory specified and approved parts. See
figure 1 for component layout.
Remember these instructions at all times:
Never perform any maintenance
procedures until the
electrical power to the unit is turned off.
Never perform any maintenance procedures until the gas
valve in gas supply line is turned off.
Never remove any panel from the unit while it is ope rating.
Never remove panels or parts from the unit that are not
discussed in this manual.
Never cover the unit since it is designed to operate year
round.
Your unit is of complex design. To ensure that it performs
safely and give long-lasting service, some of the mainte-
nance work must be performed by a qualified serviceman.
When a serviceman
is referred to in this manual, it is
describing a service technician that
has had special
training or a number of years experience
in servicing
this type of equipment. It is your responsibility to select a
qualified service company that can provide a serviceman of
this caliber.
THERMOSTAT
Room thermostats are delicate temperature-sensing
con-
trols. Their main function is to energize and de-energize the
heating or cooling circuit to maintain the temperature setting
you select.
Many thermostats contain a room thermometer
to indicate
the approximate room temperature, and a temperature scale
at the adjustment indicator to select the desired indoor air
temperature. In addition, most thermostats have a selector
mode switch with Heat, Off and Cool positions, and a fan
switch with On and Auto positions.
HEAT EXCHANGER
COIL
o
o
o
o
o
//
OUTDOOR
COIL
BLOWER
UNIT CONTROL
BOX
FLUE BOX
FURNACE
GAS VALVE
COMBUSTION
FAN BLOWER
PRESSURE
SWITCH
2
Dwg. No.21X660305
P02