EverFocus EKB500 Instruction Manual
EverFocus EKB500 Instruction Manual

EverFocus EKB500 Instruction Manual

Dvr and telemetry keyboard
Hide thumbs Also See for EKB500:

Advertisement

Quick Links

EKB500
DVR and Telemetry Keyboard
FW 1.5
New operating concept !

Advertisement

Table of Contents
loading

Summary of Contents for EverFocus EKB500

  • Page 1 EKB500 DVR and Telemetry Keyboard FW 1.5 New operating concept !
  • Page 2: Safety Warnings

    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. This Product is RoHS compliant. Ihr EverFocus Produkt wurde entwickelt und Your EverFocus product is designed and hergestellt mit qualitativ hochwertigen Materialien...
  • Page 3: Table Of Contents

    DVR MAIN MONITOR OPERATION ..................25 PTZ OPERATION / SETUP ....................27 7.6.1 EverFocus EPTZ series ....................28 7.6.2 EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation ......33 7.6.3 Pelco-D / -P protocol compatible devices’ operation............34 7.6.4 LG protocol compatible devices’ operation ..............36 7.6.5...
  • Page 4 EKB500_ma_en_rev1.5_3.doc...
  • Page 5: Introduction

    The EKB 500 universal keyboard was developed for both DVR remote control and telemetry control of speed domes and telemetry receivers. Ergonomic key alignment and the integrated jog/shuttle allow the convenient EverFocus DVR operation. 2 independent RS-485 interfaces enable installations with different telemetry protocols.
  • Page 6: Delivery Scope

    2.4 DELIVERY SCOPE 1 x EKB-500 universal keyboard 1 x 12 VDC power supply 1 x RJ-45 connector, 120 Ohm terminated 1 x RS-485 connection kit incl. connector box and 1 m connection cable 1 x manual 1 x packaging EKB500_ma_en_rev1.5_3.doc...
  • Page 7: Operating Elements

    3 OPERATING ELEMENTS 1. DVR, MON, CAM Operation mode toggle key: from firmware version 1.5 inactive, function reserved : Selection monitor Selection camera 2. 3-axis Joystick for speed dome and telemetry receiver control 3. LCD display Double-spaced LCD display for status message display Operating facility for playback and DVR menu control.
  • Page 8: Keyboard Connectors

    4 KEYBOARD CONNECTORS 4.1 RS-485 PORTS EKB-500 provides two independent RS-485 ports with 2 RJ-45 plugs each (loop-through). Pin assignment: Pin 1: 12 VDC Pin 3: RS-485 + Pin 6: RS-485 - Pin 7: Ground Pin assignment RJ-45 connector connector box Delivery comprises a connector box for RS-485 and 12 VDC power supply connection enabling power supply connection either directly to the EKB 500 keyboard or through the connector box.
  • Page 9: Installation

    5 INSTALLATION 5.1 GENERAL RS-485 BUS INSTALLATION EKB 500 uses an RS-485 simplex wiring; the signal is transferred via a single twisted pair line. CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal application. A shielded cable should be used if the installed cables are expected to be highly susceptible to interferences.
  • Page 10 In case the maximum number of 32 bus participants is exceeded, the number of connected devices can be increased by using RS-485 distributors. Each distributor output physically provides one RS-485 bus which enables the additional connection of 31 further devices (the distributor output represents one bus participant itself).
  • Page 11: Eptz 500 / 1000 / 3000 / 3500 Speed Dome Camera Connection

    5.2 EPTZ 500 / 1000 / 3000 / 3500 SPEED DOME CAMERA CONNECTION Applied protocol type: EVF2 (standard) 5.3 ED-2200, ED-2250, SAMSUNG SCC-641, SCC-643 , SCC-6405 CONNECTION Applied protocol type: A-Type EKB500_ma_en_rev1.5_3.doc...
  • Page 12: Connection Of Pelco-D / -P Protocol-Compatible Devices

    5.4 CONNECTION OF PELCO-D / -P PROTOCOL-COMPATIBLE DEVICES Basic functions of speed domes and telemetry receivers compatible to Pelco-D / -P protocol can be controlled with the EKB 500 keyboard if a simplex RS-485 connection option is provided. For general connection, please refer to the chart illustrated above.
  • Page 13: Everfocus Dvr Connection

    5.5 EVERFOCUS DVR CONNECTION The EKB 500 keyboard can control the following digital video recorders: EDSR series (despite EDSR100 19" model) EDR series (MPEG-4 series) EDVR series Paragon series Installation with standard network cable: For short distances, EKB 500 can directly be connected using a standard network cable (patch cable, uncrossed!).
  • Page 14 System settings required for start-up: DVR: MENU > RS232/RS485: RS485 BAUD RATE 9600 BPS > Baud rate must be the same as baud rate of the respective EKB 500 port (default setting or both keyboard and DVR is 9600) STOP BIT PARITY NONE DATA BIT...
  • Page 15: Connection Of Several Keyboards

    5.6 CONNECTION OF SEVERAL KEYBOARDS If several keyboards (max. 8) are used in a system, the RS-485 bus has to be looped through from keyboard to keyboard. Using both RS-485 interfaces (port 1 and 2), the 2nd bus connection must be effected separately as illustrated above by means of EDA-998 connection kits.
  • Page 16: Menu Settings

    6 MENU SETTINGS After electrical installation and start-up, both the connected devices and the keyboard itself have to be set up. Hold the key and press the key to enter the keyboard menu. COM Port Setting Device Setting Use the joystick and the key for menu navigation.
  • Page 17: Com Port Setting - Rs-485 Interface Setting

    Samsung SCC-641/643/6405 Pelco-D Pelco-P Panasonic L-Type LG Electronics ATTENTION: Protocol type setting is irrelevant for EverFocus DVR control; only baud rate setting is relevant! Press to confirm the selection and to cancel. Port : 1 Changed [ ENT ] to save 6.3 DEVICE SETTING...
  • Page 18: Monitor Setting (Changed From Fw 1.5)

    Setup of the RS-485 interface connected to telemetry RS485 Connected to cameras, port 1 or 2, 0 for OFF (fixed camera). Port : _ [ 0 (off) ] , 1, 2] Enter 0 (off) for fixed cameras (numeric entry compulsory). Press Enter to confirm the setting and to cancel.
  • Page 19: Dvr Setting

    6.3.3 DVR Setting Define the digital video recorders to be controlled by the keyboard in this menu. DVRs can only be managed by EKB 500 after definition in this menu. By this, an administration of system access rights can be set up, as only DVRs defined in this menu are available for access. DVR number, entry 1 ~ 999 (independent of DVR Name : _ _ _ DVR RS-485 address).
  • Page 20: Dvr List & Delete

    After pressing the key, the first monitor is displayed. Name DVR Mon Displays: Name: monitor number 004 02 < DVR: DVR to which the monitor is connected. DVR monitor output Del Monitor: 004 Press to delete the monitor. [ ENT ] to delete. Press again to delete the monitor and return to monitor list.
  • Page 21: Keyboard Setting

    6.4 KEYBOARD SETTING This menu allows general keyboard and security settings. 6.4.1 Sub Keyboard Setting This keyboard ID : 0 This menu provides settings for multiple keyboard ( 0 – 7 , 0 for master ) installations. Keep the default value "0" for keyboard ID and number of sub keyboards for single keyboard installation.
  • Page 22: Lock Password

    6.4.3 Lock password If this password is activated, the keyboard will lock after 30 seconds with no keyboard operation. Any key press after locking will display a password inquiry at the LCD display. > KEYBOARD SETTING > LOCK PASSWORD > Enter a max.
  • Page 23: Keypad Test

    6.4.6 Keypad test Use this menu for testing the keys’ functionality. MENU > KEYBOARD SETTING > KEYPAD TEST > Enter Press the keys to be checked. _ _ _ _ _ _ _ _ _ ] Pressed If the keys work correctly, the LCD display shows the [ Esc ] to exit key function in clear text.
  • Page 24: Operation

    7 OPERATION 7.1 NEW EKB-500 OPERATION CONCEPT (FROM FIRMWARE 1.5) With firmware 1.5 the operation of keyboard will change. Overview of the changes: 1. Main- , Call- and Matrix monitors are operated with same input procedures. 2. Cameras are operated with same input procedure for all types of monitors. 3.
  • Page 25: Dvr Password Input

    ___ [ CAM / MON ] All DVR functions are active now as described below. EKB-500 provides a separate keypad for DVR control. The keys correspond to the EverFocus DVR front panel keys as regard to labelling and functionality. Besides these keys, further keys like are required for different functions.
  • Page 26 The essential functions are described below; for further details please refer to the DVR manual. Please note that this description doesn’t provide a full function description of the EverFocus DVRs. Function Keys / operation DVR setup menu Full screen Input channel number; key is delayed for approx.
  • Page 27: Ptz Operation / Setup

    > COM PORT SETTING for interface and protocol type setting > DEVICE SETTING > CAMERA SETTING for speed dome / telemetry receiver connection settings EKB 500 is optimised for EverFocus EPTZ series speed dome control. Furthermore, basic functions of other supported speed dome types can be operated.
  • Page 28: Everfocus Eptz Series

    7.6.1 EverFocus EPTZ series The following functions are available after CAM : 0001 MON : 0001 camera selection in CAM-MON mode: [ CAM / MON / DVR ] EPTZ dome operation outline Function Keys / operation Open dome menu (hold) +...
  • Page 29 7.6.1.1 EPTZ on-screen display Start EPTZ menu: If DVR Main monitor is selected ("DVR" in LCD - display): (hold) + If no DVR Main monitor is selected: (hold) + Switch between the settings: Change the settings: Leave the menu: Menu item EXIT > ENTER or (hold) + 7.6.1.2 Positions (presets) Save presets...
  • Page 30 Start preset Camera:0001 go to > enter preset number > Position:___[1-192] 7.6.1.3 Home position The home position is the position (preset) which is approached after a pre-defined duration upon last speed dome operation. (hold) + Back to home if no >...
  • Page 31: Preset Tours

    7.6.1.5 Preset tours The EPTZ series supports up to 16 programmable preset tours with up to 16 presets each. For these tours, 2 operation modes are available: 1) Mode 1 (One way): after approaching all programmed presets, the tour restarts at the first programmed preset.
  • Page 32 7.6.1.6 Alarm contact settings This function allows the EPTZ dome alarm contact assignment to presets or preset tours. Program alarm / preset / tour link F1 > enter alarm contact number 1 ~ 4 Link Alarm:_ [1-4] to Position [↑↓]:___ Use the to switch between preset (position) and preset tour (tour)
  • Page 33: Everfocus Ed 2200/2250, Samsung El. Scc-641/643/6405 Operation

    7.6.2 EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation Required protocol type in "COM PORT SETTINGS": A-TYPE / SAMSUNG 7.6.2.1 On-screen display Start menu: If DVR Main monitor is selected ("DVR" in LCD - display): (hold) + If no DVR Main monitor is selected:...
  • Page 34: Pelco-D / -P Protocol Compatible Devices' Operation

    7.6.2.4 Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Start A-B autopan Speed:___[1-239] > enter pan speed [ENT] to start.
  • Page 35 7.6.3.2 Presets Save presets Camera:0001 Save to (hold) + Position:___[1-192] > enter preset number > Delete preset Camera:0001 (hold) + Del Position:___ > enter preset number > Start preset Camera:0001 go to Position:___[1-192] > enter preset number > 7.6.3.3 Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display.
  • Page 36: Lg Protocol Compatible Devices' Operation

    7.6.3.5 Pattern / Preset Tour Define patterns, which also can contain a preset tour, in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Activate pattern Camera:0001 Run Tour:__[1-16] > enter pattern number > ATTENTION: At some third party domes with implemented Pelco-D the Preset tour starts with alternative command: >...
  • Page 37: Specifications

    2 lines with 20 characters each RS-485 2 independent RS-485 ports with 2 RJ-45 sockets each RS-232 1 x RS-232, Sub-D9 socket (service) RS-485 protocols EverFocus, ED2200/2250, Samsung Electr., Pelco-D, Pelco-P LG, Panasonic Power source 12 VDC +-10%, via power supply 110/230 VAC Power consumption 10 W max.
  • Page 38: Appendix A: Factory Settings

    9 APPENDIX A: FACTORY SETTINGS PORT settings: Port 1: 9600 baud, EverFocus Port 2: 9600 baud, EverFocus DEVICE SETTINGS / DVR DVR1: 16Ch., port 1 Addr.1 DVR2: 16Ch., port 1 Addr.2 DVR3: 16Ch., port 1 Addr.3 DVR4: 16Ch., port 1 Addr.4 DVR5: 16Ch., port 1 Addr.5...
  • Page 39 Cam49: connected to DVR4, input1, PTZ-ID: OFF ..Cam64: connected to DVR4, input16, PTZ-ID: OFF Cam65: connected to DVR5, input1, PTZ-ID: OFF ..Cam80: connected to DVR5, input16, PTZ-ID: OFF Cam81: connected to DVR6, input1, PTZ-ID: OFF ..Cam96: connected to DVR6, input16, PTZ-ID: OFF PASSWORDS: disabled BUZZER:...
  • Page 40 EverFocus Electronics Corp. China Office: Head Office: Room 609, Technology Trade Building, 12F, No.79 Sec. 1 Shin-Tai Wu Road, Shandgdi Information Industry Base, Hsi-Chih, Taipei, Taiwan Haidian District, Beijing,China www.everfocus.com.tw www.everfocus.com.cn USA Office: 1801 Highland Ave. Unit A Japan Office: Duarte, CA 91010, U.S.A.

Table of Contents