Furniture Mounting; Connections - Extron electronics VersaTools MTP DA4 User Manual

Video, audio, and/or serial link mini twisted pair distribution amplifiers
Hide thumbs Also See for VersaTools MTP DA4:
Table of Contents

Advertisement

VersaTools
®
MTP DA4 and MTP DA8, cont'd

Furniture mounting

Do not attach the rubber feet. Furniture mount the DA using
the optional mounting kit (part #70-077-01) as follows:
1.
Remove rubber feet if they were previously installed on
the bottom of the DA.
2.
Attach the furniture mounting brackets to the DA with the
provided machine screws (figure 5).
Figure 5 — Attaching the furniture mounting
brackets to an MTP DA
3.
Hold the DA with the attached brackets against the
underside of the table or other furniture. Mark the
location of the screw holes of the bracket on the mounting
surface.
4.
Drill 3/32" (2 mm) diameter pilot holes, 1/4" (6.3 mm)
deep in the mounting surface at the marked screw
locations.
5.
Insert #8 wood screws into the four pilot holes. Tighten
each screw into the mounting surface until just less than
1/4" of the screw protrudes.
Align the mounting screws with the slots in the brackets
6.
and place the DA against the surface, with the screws
through the bracket slots.
7.
Slide the DA slightly forward or back, then tighten all four
screws to secure the unit in place.
®
®
8
VersaTools
VersaTools
MTP DA4 and MTP DA8 • Installation
MTP DA4 and MTP DA8 • TP Cable Advantages
M T
P D
A S
E R
IE S

Connections

Do not connect these devices to a computer data or
CAUTION
telecommunications network.
MTP DA8
A/V INPUT
1
2
3
POWER
+ -
12V
0.93A MAX
1
2
MTP DA4
A/V INPUT
POWER
+ -
12V
0.93A MAX
1
2
Figure 6 — DA rear panel features
Power connector — Plug the included external 12 VDC power
1
supply into this 2-pole captive screw connector. See Power
supply wiring, on page 10, to wire the connector.
A/V Input connector — Connect one end of the cable, carrying
2
the video and audio or serial TP link from the transmitting
device, to this RJ-45 female connector.
See TP cable termination, on page 11, to wire the RJ-45 connectors.
A/V Output connector — Connect one end of a , carrying the
3
video and audio or serial TP link from the transmitting device,
cable to this RJ-45 female connector on the receiver.
Connect the free end of the same cable, carrying the distributed
video and audio or serial TP link, from the DA to the receiver.
See TP cable termination, on page 11, to wire the RJ-45 connectors.
The MTP DA's output does not provide any pre-peaking
control. The total recommended distance for a complex
system with multiple DA outputs is the same as for a
simple system with a single transmitter and receiver.
See the recommended transmission ranges in the table on
page 3. The table's recommendations apply to a complete
transmission system, which can include a single
transmitter, DA, and multiple receivers or a complex
system including multiple daisy-chained receivers.
®
®
VersaTools
VersaTools
MTP DA4 and MTP DA8 • Connections
MTP DA4 and MTP DA8 • Installation
A/V OUTPUTS
4
5
6
7
8
OUTPUT MUTE
1 2 3 4 5 6 7 8 A
3
4
A/V OUTPUTS
1
2
3
4
OUTPUT MUTE
1 2 3 4 A
3
4
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versatools mtp da8

Table of Contents