Product Data Sheets - KitchenAid KSSO48FMX03 Use & Care Manual

Side by side built-in refrigerator
Hide thumbs Also See for KSSO48FMX03:
Table of Contents

Advertisement

Available languages

Available languages

PRODUCT DATA SHEETS
Base Grille Water Filtration
System
Model WF-LC400V/LC400V
Capacity
400 Gallons
(1514 Liters)
Tested and certified
by NSF International
against ANSI/NSF
Standard
42 for the
reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
ANSl/NSF
Standard
53 for the reduction
of Lead, Mercury,
Atrazine,
Benzene,
Toxaphene,
p-dichlorobenzene,
2, 4-D, Cysts, Turbidity
and Asbestos.
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
->50%
2.1 mg/L
2.0 mg/L _+10%
0.06 mg/L
0.05 mg/L
97.1%
97.6%
Particulate Class 1"
4,100/mL**
99.9%
_>85%
5,366,667/mL
At least 10,000
2,300/mL
99.3%
particles/mL
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.Olmg/L
0.152 mg/L1-
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.34%
99.34%
Lead: @ pH 8.5
0.01mg/L
0.143 mg/L1-
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.30%
99.30%
Mercury: @ pH 6.5
0.002 mg/L
0.0061 mg/L
0.006 mg/L _+10%
0.0004 mg/L
0.0003 mg/L
93.5%
96.7%
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.0058 mg/L _+10%
0.0008 mg/L
0.00051 mg/L
85.8%
91.2%
Benzene
0.005 mg/L
0.0162 mg/L
0.015 _+10%
0.0005 mg/L
0.001 mg/L
96.3%
96.3%
p-dichlorobenzene
0.075 mg/L
0.220 mg/L
0.225 _+10%
0.0005 mg/L
0.0005 mg/L
99.7%
99.7%
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 _+10%
0.0014 mg/L
0.001 mg/L
90%
92.96%
Atrazine
0.003 mg/L
0.0086 mg/L
0.009 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
94.25%
94.25%
2, 4-D
0.07 mg/L
0.197 mg/L
0.210 _+10%
0.058 mg/L
0.0137 mg/L
70.6%
93.06%
Asbestos
99%
26 x 107
107to 10_fibers/Ll-1 -
0.18 x 107 mg/L
0.18 x 107 mg/L
99.93
99.93%
Cysts:[:
99.95%
111,000/mL
50,000/L min.
1 mg/L
1 mg/L
99.99%
99.99%
Turbidity
0.5 NTU
11.00 NTU
11 _+1 NTU
0.40 NTU
0.35 NTU
96.4%
96.8%
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted.
(17.2°C).
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-LC4OOV The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge LC4OOV,part
#4396548. 2006 suggested retail price of $39.99 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected
waters that may contain filterable cysts.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
Refer to the front
cover or "Accessories"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 GPM (1.89 L/min.)
@ 60 psi.
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
1-These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
1-1-Fibers greater than 10 um in length
SBased on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
2O