Electrical
Shock Or Personal
Injury
Hazard
Disconnect
electrical
supply
before
servicing
or cleaning
the unit.
Failure to do so could result
in
electrical
shock or personal
injury
from cleaner
suddenly
starting.
Frequently
check and remove
hair, string
and tint build-up
in the brush area.
If
build-up
becomes
excessive,
follow the
steps below°
TO REMOVE BELT:
Disconnect
power cord from electrical
outlet,
and place on paper to protect
the
floor surface°
Place vacuum
in the ful!
upright
posiiton
Plate
Agitator
Turn the
unit over so
the agitator
and base
plate are
facing
upward.
Locate the
two latches
and the
two locking
tabs which
secure
the
base plate.
Latches
Two Locking Tabs
To unlock the base plate, slide the left
latch to the right and the right latch to the
left. Push in on the locking tabs toward
the center of the vacuum.
Pull the base plate away from the nozzle
housing.
The sides of the base
plate
need to be pulled slightly
outward
to clear
the wheel&
Belt
Agitator
The agitator
and belt are now exposed.
Carefully
remove
any residue
that may
exist in the belt area,
Motor "
Shaft
Position
hands
on the agitator.
If the belt
is still attached
to the motor shaft, there
will be tension
on the agitator.. If the belt is
not broken,
remove
it from the motor shaft
before
lifting the agitator.
Carefully
lift the right end of the agitator
and then
lift the left end.
Carefully
remove
the end cap and washer
from each end and lay them aside. See
the exploded
view,
Personal
Injt,ry
Hazard
Be careful
when
removing
the agi-
tator as the belt tension
is high.
Failure
to do so could
result
in
personal
injury
from the agitator
releasing
quickly
and snapping
away.