TrOubleshooting -tips
Save time and money! Review the charts on the following
ages first and you may not need to call for service.
Problem
Possible
Causes
What To Do
Zoneline does
The unit is
* Make sure the Zoneline
plug is pushed
completely
notstart
unplugged,
into the outlet.
The power cord is not
* Rem_we the room cabinet
and make sure that the
firmly attached,
yellow, connector
on the end ot the power cord is
firefly engaged.
The fuse is blown/circttit
• Check
the house fllse/drcuit
breaker
box and replace
breaker
is tripped,
the fllse or reset the breaker:
The unit is waiting
for
• This is nomml.
The Zoneline
will start again afier
the compressor
overload
it resets.
protector
to reset,
Power
failure.
• If power
fifihu'e
occm_,
set the
m ode
control
to
STOP.
When
power
is restored,
set the
mode
control
to the
desired
setting.
• There
is a protective
time delay (up to 3 minutes)
to
prevent
trii)ping
ot the compressor
overload.
For this
reason,
the unit may not start nomml
heating
or cooling
ti)r 3 minutes
al*er it is tin'ned
back on.
The current
interrupter
device is tripped.
• Press the RESETbutton
located
on the power cord i)lug
or the box near the plug.
• If the RESETbutton
will not stay engaged,
discontinue
ttse
of the Zoneline
and contact
a qt_dified
sexaice technician.
Zoneline does not cool
Indoor
airflow
• Make sure there
are no curtains,
blinds
or flu'niture
or heat as it should
is restricted,
blocking
the fl'ont el the Zoneline.
Burning odor at the start
of heating operation
Outdoor
airflow
is
restricted
or recirctdated.
• Make
sm'e
the
rear
grille
is not
restricted.
This
can
cause
the
trait
to cycle
off due
to the
compressor
overload
l)rotectoi:
• Outdoor
grille must have a minimum
of 65% fl'ee area.
Non-OE
grilles may be too restrictive
for i)roper
pertbmmnce.
Consult
p)tu" salesperson
tot assistance.
The temp control may
• Tm'n the control
to a lower or higher
setting.
not be set properly,
NOTE: Thetemperaturel/mitermay be bruitingthe temperaturerange.
The air filter is dirty.
• Clean the filter at least e\'e_y 30 days.
See the Operating Instructions
section.
The room may have
• When
the Zoneline
is fi_t turned
on vou need to
been hot or cold.
allow time tin" the room
to cool down or wama up.
Outdoor
air is
• Set the vent control
to the closed position.
entering
the room.
Dust is on the surface
of the heating
element.
• This can cause a "burning"
odor at the beginning
of
the heating
operation.
This odor should quickly fade.