LIMITED WARRANTY ON CRAFTSMAN SUBMERSIBLE SUMP PUMPS During the second year after the date of purchase, Sears will furnish, free of charge, a replacement part for any defective part.
INSTALLATION THE SUMP FLOAT SWITCH INSTALLATION AND OPERATION The sump should be located at the lowest place in the base- (Models 390.304551 and 390.304611; ment or area to be drained. Floor drains from other areas in For Model 390.304691, see Page 7) the basement may be tiled into the sump.
Page 4
ELECTRICAL ELECTRICAL CONNECTIONS IAWARNINGIRJsk of electric shock. This pump is sup- pried with a grounding conductor and ground_g-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. UL Listed Analyzer The Sump Pump hasa 3-prong electric plug.
SERVICE General Pump Cleaning [_kWARNING [Risk of electric shock. When servicing 1. NOTICE: Attempting to disassemble motor will void war- rarity. pump always disconnect power to electrical outlet remove pump electric cord from outlet. 2.To clean impeller, remove eight screws holding baseplate 1.
Page 6
REPAIR PARTS Sears Submersible Pump Craftsman Submersible Pump Model 390.304551 Model 390.304611 Pump wilthave eitherY-Cordarrangement (item9) or PowerCord f Switcharrangement as shownabove. 1473 0195 IT130_J5 PARTS LIST PARTS LIST Part 30455 Part 30461 Part No. Part No. Description Description U30-956ZP Pump Body Screw #8 xl/2 Type A (7 Req.)
REPAIR PARTS Vertical Switch Craftsman Submersible Pump Model 390.304691 Assembly Assembly Sequence 018 0893 I_ CAUTION J Make sure pin holds float rod in switch 2713 _19€ housing; otherwise pump will not shut off, PARTS LIST To check switch operation, run pump through one com- plete cycle after Installation.