Maintenance; Storage - Craftsman 921.166420 Owner's Manual

20-gallon 1.5 hp oil-free, direct drive
Hide thumbs Also See for 921.166420:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance
NOTE:
Any
service
procedure
not
covered
in the
maintenance
schedule should be performed
by qualified
service personnel.
The air compressor
should be turned off, unplugged
from
the power
source,
air bled from the tank and allowed
time to cool before any maintenance
is performed.
Items to Check/Change
Check Tank Safety Valve
Overall Unit Visual Check
Drain Tank
Check Power Cord for Damage
Before each use
or daily
X
X
X
X
Do not attempt to remove or adjust the safety valve.
Check the safety valve by performing these three steps:
1. Plug the compressor in and run until shut-off pressure
is reached.
2. Wearing safety glasses, pull out on the safety valve ring
to release pressure from the tank.
3.
The
safety
valve
should
close
automatically
at
approximately
at 40-50 PSI. If the safety valve does not
allow air to be released when you pull out on the ring, or
does not close automatically,
it must be replaced.
To ensure efficient operation
and longer life of the air
compressor
unit, a routine maintenance
schedule should
be followed.
The following
schedule is geared toward a
consumer whose compressor is used in a normal working
environment on a daily basis.
This compressor is equipped with an automatic reset
thermal overload protector which will shut off motor if it
becomes overheated. If the thermal overload protector is
actuated, the motor must be allowed to cool down before
start-up is possible.
NOTE: The motor will automatically restart without warn-
ing if the unit is left plugged in to an outlet with the Auto-
On/Off switch in the on position
Storage
For storing the air compressor, be sure to do the following:
1. Turn the unit off and unplug the power cord from the
receptacle.
2. Remove all air hoses, accessories, and air tools from
the air compressor.
3. Perform the daily maintenance schedule.
4. Open the drain valve to bleed all air from the tank.
5. Close the drain valve.
6. Store the air compressor in a clean and dry location.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents