Error Condition
A file system is not mounted
after rebooting.
The disk array performs a
self reboot because the disk
array was busy or it logged a
panic message.
The disk array responds "Not
Ready" or the disk array has
displayed "Not Ready" and
timed out.
The host detects a parity
error.
The host hangs or devices are
declared and the host hangs.
Troubleshooting
Recommended Action
Verify that the host was restarted correctly.
Verify that the file system attributes are correct.
Reboot the host.
Contact HP.
Check the HBA and make sure it was installed properly.
Reboot the host.
Make sure there are no duplicate disk array TIDs and that disk array
TIDs do not conflict with any host TIDs.