Vulcan-Hart VSX Series Service Manual page 25

Vsx boiler base series convection steamers
Table of Contents

Advertisement

3.
Remove the lead wires from the heating element and check the element resistance using a VOM.
A.
If resistance readings are not correct, replace heating element.
1)
To replace an element, drain water from boiler shell.
2)
Remove cover of contactor box, remove electric wires to that element's terminals, remove bolts
through flange of element and pull element forward.
NOTE: When replacing an element, always use a new gasket and ensure that the flange and tube surfaces which
contact the gasket are clean. If removed element shows a pronounced scale build-up on its heating tubes, the
other elements should be removed and mechanically cleaned to remove the scale. This will prolong their life. DO
NOT immerse elements in a chemical solution to descale.
4.
After new element is installed, check unit for proper operation.
NUMBER
TOTAL
VOLTAGE
OF
KW
ELEMENTS
208
18
2
240
18
2
480
18
2
*220/380
18
2
240/415
208
24
4
240
24
4
480
24
4
*220/380
4
24
240/415
208
24
2
240
24
2
480
24
2
*220/380
24
2
240/415
208
36
4
240
36
4
480
36
4
*220/380
36
4
240/415
208
42
4
240
48
4
480
48
4
*220/380
48
4
240/415
NOTES:
1.
Values in the table are nominal. Tolerance is +/-10 %.
2.
Asterisk (*) indicates 3 phase/4wire.
3.
Each heater has three internal elements.
4.
6.0 KW heaters used on older models and included for reference.
VSX SERIES STEAMER - SERVICE PROCEDURES
AMPERAGE
KW
PER LINE
PER
ELEMENT
1 PH
3 PH
9
87
50
9
75
44
9
22
9
25
6
116
68
6
100
58
6
29
6
57.8
12
116
68
12
100
58
12
29
12
34
9
100
9
87
9
44
9
50
10.5
117
12
116
12
58
12
67
Page 25 of 80
RESISTANCE
PER
ELEMENT
(OHMS)
14.42
19.20
76.80
19.20
21.63
28.80
115.20
28.80
10.82
14.40
57.60
14.40
14.42
19.20
76.80
19.20
12.36
14.40
57.60
14.40

Hide quick links: