Firmware Versions; Platform - HP SN3000B Troubleshooting Manual

Troubleshooting and diagnostics guide
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

Message
The FS8-18 (type 43) blade is not supported by the target firmware. Please use slotshow to find out
which slot it is in and remove it first.
Probable cause and recommended action
The firmware download operation was attempting to downgrade a system to Fabric OS v6.1.1_enc
or earlier with one or more Brocade FC8-18 AP blades (blade ID 43) in the system. Brocade
Encryption Blade FC8-18 AP blades are not supported on firmware v6.1.1 or earlier, so the
firmware download operation failed.
Use the slotShow command to display which slots the Brocade FC8-18 AP blades occupy. Physically
remove the blades from the chassis, or use the micro-switch to turn the blade off. Retry the
firmware download operation.

Firmware versions

These messages refer to differences between the current firmware and the firmware you are
applying to the switch.
Message
Cannot upgrade directly to v6.3.0. Upgrade your switch to v6.2.0 first before upgrading to the
requested version.
Probable cause and recommended action
If the switch is running v6.1.0 or earlier, you are not allowed to upgrade directly to v6.3.0 because
of the "two-version" rule.
Upgrade your switch to Fabric OS version v6.2.0 before upgrading to v6.3.0
Message
Non-disruptive firmwaredownload is not supported when downgrading to 6.1. Please use
firmwaredownload -s to download the 6.1 firmware.
Probable cause and recommended action
If the switch is running v6.2.0, you are not allowed to downgrade directly to v6.1.x without causing
disruption to your fabric.
Downgrade using the firmwareDownload -s command. For more information on using this
command, refer to the Fabric OS Administrator's Guide.
Message
Firmwaredownload of blade application firmware failed. Reissue firmwareDownload to recover.
Probable cause and recommended action
The firmware download operation was attempting to upgrade the SAS image while the blade was
operational.
Retry the firmwareDownload command again.

Platform

This message pertains to switch features or fabric-wide settings that must be removed or disabled
before downgrading the firmware.
Fabric OS Troubleshooting and Diagnostics Guide
53-1002150-02
Considerations for downgrading firmware
5