Select a location where noise, vibration and hot dis-
charged air will not be an issue.
Do not install where high frequency equipment is used
(wireless equipment, welding machine, medical facility)
as it may interfere with the unit's operation.

Rooftop Installations

If it is necessary to install the outdoor unit on a roof structure,
ensure the roof structure can support the weight and that proper
consideration is given to the weather-tight integrity of the roof.
Since the unit can vibrate during operation, sound vibration
transmission should be considered when installing the unit.
Vibration absorbing pads or springs can be installed between
the condensing unit legs or frame and the roof mounting as-
sembly to reduce noise vibration.

Tools

Level gauge
Screwdriver
Electric drill, hole core drill (65mm)
Flaring tool set
Torque wrenches
1.8kgf.m 13 ft-lb
4.2kgf.m 30 ft-lb
5.5kgf.m 40 ft-lb
6.6kgf.m 48 ft-lb
Hexagonal wrench (4mm)
No.
Description
1
Installation Plate
2
Clip Anchor
3
Self-tapping Screw A ST3.9x25
4
Seal (on selected models
5
Drain joint
*Connection Pipe Assembly
Liquid Side 1/4" (Φ 6.35)
6
Gas Side
3/8" (Φ 9.52)
1/2" (Φ12.7)
7
Remote Control
8
Self-tapping Screw B ST2.9x10
9
Remote Control holder
*Parts must be purchased separately. Consult dealer for pipe sizes.
(Minimum pipe wall thickness of 1/32" (0.7 mm) is recommended)
NOTE: Parts listed are provided with the unit except where
noted. Any additional parts required must be purchased sepa-
rately.
Gas leak detector
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape
Spanner (half union)
PARTS
Quantity
1
8
8
1
1
*See
Note
1
2
1
O
NOTE: Copper lines must be insulated independently.
IMPORTANT NOTES:
• A stud finder should be used to locate studs and prevent
unnecessary damage to the wall.
• A minimum pipe run of 10' (3 meters) is required to mini-
mize vibration and excessive noise.

Indoor Unit Installation

Installation of Mounting Bracket
1. Install the mounting bracket horizontally and securely to
the wall, allowing room for access on either side of the
unit.
2 If the wall is constructed of brick, concrete or similar
material, drill eight (8) 3/16" (5 mm) diameter holes in the
wall. Insert the clip anchor for appropriate mounting
screws.
3. Install the mounting bracket on the wall with eight (8)
type "A" screws.
3
Wrapping
Tape
Figure 3
Additional
Drain
Pipe
Loop the
connective
cable.