Shown In Fig - Sylvania LC200SL8 Service Manual

20" color lcd television
Hide thumbs Also See for LC200SL8:
Table of Contents

Advertisement

With
Iron Wire:
1.
Using desoldering braid, remove the solder from
all pins of the flat pack-IC. When you use solder
flux which is applied to all pins of the flat pack-IC,
you can remove it easily. (Fig. S-1-3)
2.
Affix the wire to a workbench or solid mounting
point, as shown in Fig. S-1-5.
3.
While heating the pins using a fine tip soldering
iron or hot air blower, pull up the wire as the solder
melts so as to lift the IC leads from the CBA
contact pads as shown in Fig. S-1-5.
4.
Bottom of the flat pack-IC is fixed with glue to the
CBA; when removing entire flat pack-IC, first apply
soldering iron to center of the flat pack-IC and heat
up. Then remove (glue will be melted). (Fig. S-1-6)
5.
Release the flat pack-IC from the CBA using
tweeFers. (Fig. S-1-6)
Note:
When using a soldering iron, care must be
taken to ensure that the flat pack-IC is not
being held by glue. When the flat pack-IC is
removed from the CBA, handle it gently
because it may be damaged if force is applied.
To Solid €
Mounting Point
Hot Air Blower
\
\
or
Iron Wir/
Soldering
Iron
\
Fig. S-1-5
B_
Fine Tip
C
Soldering Iron
\
Flat Pack-IC
Fig. S-1-6
,
1.
2.
3.
Installation
Using desoldering braid, remove the solder from
the foil of each pin of the flat pack-IC on the CBA
so you can install a replacement flat pack-IC more
easily.
The "O" mark on the flat pack-IC indicates pin 1.
(See Fig. S-1-7.) Be sure this mark matches the 1
on the PCB when positioning for installation. Then
presolder the four corners of the flat pack-IC. (See
Fig. S-1-8.)
Solder all pins of the flat pack-IC. Be sure that
none of the _ins have solder bridges.
Example
Pin 1 of the Flat Pack-IC
is indicated by a "•"
mark.
Fig. S-1-7
Presolder
I
CBA
Flat Pack-IC
Fig. S-1-8
3-3
TVN_SN

Hide quick links: