A manual bypass valve should be installed across the
heater when the pump flow exceeds 120 GPM (454 LPM).
See instructions below for setting of the manual bypass.
Make sure that the outlet plumbing from the heater con-
tains no shut-off valves or other flow restrictions that could
prevent flow through the heater (except as noted below).
To switch flow between the pool and spa, use a diverter
valve. Do not use any valve that can shut off the flow.
Do not use a shut-off valve to isolate the heater unless it is
below the level of the pool or spa.
Install a check valve to prevent back-siphoning through the
heater when the pump is off.
NOTICE: Improper operation of chemical feeders can cause
severe damage to the heater which is not covered by the
warranty. Install the chemical feeder downstream of the
heater (see "Water Chemistry," Page 17).
Install a chemical resistant one-way check valve between
the heater and the chemical feeder.
NOTICE: If you install a chemical feeder and check valve,
you must install a relief valve on the heater. See "Pressure
Relief Valve", Page 18 and 19.
NOTICE: If the heater is plumbed in backwards, it will
cycle continuously. Make sure piping from filter is not
reversed when installing heater.
WATER PIPING
Connect the heater directly to 2" PVC pipe, using the inte-
gral unions provided. Heat sinks are not required. The low
thermal mass of the heater will prevent overheating of the
piping connected to the pump even if the heater shuts
down unexpectedly.
SYSTEM 3
Modular Media
To Filter
FIGURE 15:
Typical installation
Filter
Inlet
Cool Water
In From Pool
Main
Drain
Pool
From Pool
FIGURE 16: Typical pool piping layout
From Filter Outlet
to Heater
Inlet
Corrosion Resistant,
Positive Seal
Check Valve
Sanitizer
Cool Water
In From Spa
16
3-Way
Valve
Spa
Pump
3-Way
Valve
Warm Water
Out to Pool or Spa
To Pool
To Spa
2735 1296
Chlorinator
Heater
Filter
3-Way
Valve