Pump Installation; Emergency Power - Craftsman 390.2522 Owner's Manual

Professional "hydroglass '' convertible deep well jet pump
Hide thumbs Also See for 390.2522:
Table of Contents

Advertisement

INSTALLATION
i "_ CAUTION ]NEVER run pump
dry. Running
pump
with-
out water
may overheat
unit,
damaging
seals and possibly
burning
persons
handling
pump.
l
1
[_WARNINGJNEVER
run
pump
against
closed
dis-
charge.
To do so can boil water
inside
pump,
causing
haz-
ardous
pressure
in unit
and possible
scalding
to persons
handling
pump.
Be sure the total lift from the pumping
water
level
to the
pump
does not exceed
20 feet ff the pump
is over the well,
or less if the pump
is offset from
the well. Both figures
are
for sea level - the maximum
lift at which
the pump
can op-
erate
satisfactorily,
decreases
with
the elevation
at the ap-
proximate
rate of 1 foot per 1,000 feet of elevation;
thus, ff
the lift is 17 feet and your elevation
is 3,000 feet above
sea
level,
you would
then
be pumping
17 plus
3 or 20 feet,
which
is still satisfactory
for shallow
well pumping.
Horizontal
Piping
From
Well
To Pump
On well point
installations
where
the horizontal
piping
is
more
than
25 feet,
a check
valve
should
be installed
as
shown
in Figures
3 and 4, Page 5.
When
the pump
is offset more
than 25 feet from the well,
horizontal
piping
should
be increased
in size to reduced
fric-
tion losses.
In no case should
the offset piping
be smaller
than the suction
tapping
of the pump.
Horizontal
Offset
Piping
Sizes
Shallow
Well Jets
1-1/4"
1-1/2"
2"
Up to 25 Ft.
25 to 50 Ft.
50 to 200 Ft.
Horizontal
Offset Piping
Sizes
Deep Well Jets
Discharge
Pipe Sizes
When
the pump
is set a distance
from the house,
barns,
or
other
points
of water
use, the discharge
pipe size should
be
increased
to reduce
pressure
losses.
1"
1-1/4"
1-1/2"
Up to 25 Ft.
25 to 100 Ft.
100 to 600 Ft.
PUMP INSTALLATION
SEARS jet pumps
can be used with
Captive
Air s Tanks
as
shown
in Figure 1, Page 4, and Figure 3, Page 5.
For mounting
pump
to tank, order tank fittings Kit No. 2788.
Captive
Air* Tanks
are pre-charged
with
air at the factory.
Check
operating
instructions
with
tank to determine
if air
charge
needs
adjustment.
Models
390.2519
and
390.2522
require
40 pounds
for
proper
operation.
EMERGENCY
POWER
In some
areas
and with
some
installations,
an emergency
power
supply
to guard against
power
failure is a good idea.
If you install an engine-generator
set for emergency
backup
power
for your pump,
supply
the generator
set manufac-
turer with the nameplate
data from the pump
motor.
He will
then
be able to provide
a generator
of the correct
size to
power
your pump.
Also, be sure to add the load from
any
other
accessories
(such
as lights)
that may be on the same
circuit.
Up to 50 Ft.
Suct.
Drive
1-1/4
1"
50 to 100 Ft.
Suct.
Drive
1-1/2"
1-1/4"
100 to 300 Ft.
I
Suct.
Drive
2
1-1/2
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

390.2519

Table of Contents