4.
Move the On/Auto/Off
lever to
"ON/AUTO"
position.
The com-
pressor
will start.
5.
Run the compressor
for 15 min-
utes. Make sure the drain valve is
open and there is minimal
air
pressure
build-up
in tank
6,
After 15 minutes,
close the drain
valve (clockwise).
The air receiver
will fill to "cut-out"
pressure
and
the motor
will
stop.
The compressor
is now ready for use,
Before
Each
Start-Up:
1.
Place On/Auto/Off
lever
to
"OFF".
.
.
Pull regulator
knob out, turn
counterclockwise
until it stops.
Push knob
in to lock in place.
Attach
hose and accessories.
NOTE:
The hose or accessory
will require
a quick
connect
plug
if the air outlet
is equipped
with a
quick connect.
Too much air pres-
sure causes
a haz-
ardous
risk of bursting.
Check
the
manufacturer's
maximum
pressure
rating for air tools and accessories.
The regulator
outlet
pressure
must
never exceed
the maximum
pres-
sure rating,
How to Start:
1,
Turn the On/Auto/Off
lever to
"AUTO"
and allow tank pressure
to build.
Motor
will stop when
tank pressure
reaches
"cut-out"
pressure.
2.
Pull the regulator
knob out and
turn clockwise
to increase
pres-
sure. When the desired
pressure
is reached
push
knob in to lock
in place. The compressor
is
ready for use.
NOTE:
Always
operate
the air com-
pressor
in well-ventilated
areas free
of gasoline
or other
combustible
vapors.
If the compressor
is being
used to operate
a sprayer
DO NOT
place near the spray
area.