Checking The Drives For Data Consistency - Asus Z9PR-D12 SERIES User Manual

User guide
Table of Contents

Advertisement

5.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the Objects > Adapter
menu.
The Check Consistency command is available only for virtual drives included
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command:
From the Management Menu, select Check Consistency, and then press
1.
<Enter>.
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
2.
The screen displays the available RAID sets and prompts you to select the
virtual drive to check. Press <Space> to select the virtual drive from the
Virtual Drive sub-menu, and then press <F10>.
LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drives
Virtual Drive 0
ASUS Z9PR-D12 Series
BIOS Version
A.10.09231523R
CC Of VD(s)
BIOS Version
A.10.09231523R
Virtual Drive(s) Configured
LD
RAID
Size
0
1
148.580GB
Select VD
SPACE-(De)Select,
F10-Check Consistency
#Stripes
StripSz
2
64 KB
Status
ONLINE
5-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z9pr-d12c

Table of Contents