Cr_Srcinp4 Command; Cr_Srcinp5 Command; Cr_System Command - Sanyo PLC-WXU300 - 2500 Lumens Manual

Rs232 expand
Hide thumbs Also See for PLC-WXU300 - 2500 Lumens:
Table of Contents

Advertisement

PLC-WXU300 Expand Serial Command Functional Specifications
9.7.6

CR_SRCINP4 Command

Command
"CR_SRCINP4" [CR]
Details
Get selected source of Input 4_Video
Acceptable
Response
Request data
Unacceptable
9.7.7

CR_SRCINP5 Command

Command
"CR_SRCINP5" [CR]
Details
Get selected source of Input 5_S-video
Acceptable
Response
Request data
Unacceptable
9.7.8

CR_SYSTEM Command

Command
"CR_SYSTEM"[CR]
Details
Get selected System
Acceptable
Response
%1
"000_%1"[CR]
"VIDEO" ------------- Composite Video Input is selected
"Error code"[CR]
"000_%1"[CR]
"Sÿ VIDEO" -------- S-Video Input is selected
"Error code"[CR]
"000_%1"[CR]
"VGA1" -------------- VGA1 is selected
"VGA2" -------------- VGA2 is selected
ÿ
"XGA1"-------------- XGA1 is selected
ÿ
"WXGA3" --------- WXGA3 is selected
"1080i" ------------ 1080i is selected
"1035i" ------------ 1035i is selected
Input is
"720p" ------------- 720p is selected
PC Analog
"575p" ------------- 575p is selected
"480p" ------------- 480p is selected
"575i" -------------- 575i is selected
"480i" -------------- 480i is selected
"MODE1" ------- Mode1 is selected
ÿ
"MODE5" -------------- Mode5 is selected
When there is no signal, projector returns error code"101"
[CR]
"Dÿ XGA1" ------------- D-XGA1 is selected
ÿ
"Dÿ WXGA3" ---------- D-WXGA3 is selected
"Dÿ 1080I" ------------- D-1080i is selected
Input is
"Dÿ 1035I" ------------- D-1035i is selected
HDMI
"Dÿ 720P" ------------- D-720p is selected
"Dÿ 575P" ------------- D-575p is selected
"Dÿ 480P" ------------- D-480p is selected
When there is no signal, projector returns error code"101"
[CR]
54/72