Lp Gas Connection - Electrolux RM 6501 Manual

Table of Contents

Advertisement

Cut out opening for the
side vent L500
is 341 x 451 mm.
L205 is 156 x 451 mm.
min. ventilation
height
Cut out opening for the
side vent L500
is 341 x 451 mm
40
Batten
attached to
the floor
FIG. 3a
20
The flue gases are dispersed through the upper vent
grille or the roof vent together with the ventilation air.
The top, bottom and sides of the ventilation passage
should be insulated to prevent condensation and cold
draughts.
Ventilation heights
Minimum ventilation heights in mm.
Model
Upper side vent L205
Lower side vent L500
RM 6501
1400

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the
pressure of which must be 28 mbar for Butane and 37 mbar
for Propane. Check that this is stated on the data plate.
The refrigerator is not designed for operation on
town gas or natural gas.
16
VENTILATION OF THE UNIT
Sealing gasket
e.g. of V-type
This piece is
already on the
60
refrigerator
Condenser
385
min. 510
Sealing gasket
e.g. of V-type
Floor
Installation with
Upper side vent L500
Roof vent R500
Lower side vent L500
Lower side vent L500
1400
1250
Cut out opening for the
roof vent R500
is 87 x 507 mm
min. ventilation
height
Cut out opening for the
side vent L500
is 341 x 451 mm
FIG. 3b
20
Batten attached
to the side wall
FIG. 3c
CAUTION! CHECK THAT THE GAS SUPPLIED
TO THE REFRIGERATOR IS AT THE CORRECT
PRESSURE. SEE THE REDUCING VALVE ON
THE LP GAS CONTAINER.
The gas installation should only be carried out by a
person experienced in gas fitting. It is recommended that
the gas pipe feeding the refrigerator is so arranged that
it is possible to turn off the supply of the refrigerator.
Condenser
min. 510
Sealing gasket
e.g. of V-type
View from above
Door