Troubleshooting - White Rodgers 1F73 Installation Instructions Manual

Heating & air conditioning non- programmable, auto changeover multi-stage/heat pump thermostat
Table of Contents

Advertisement

TROUBLESHOOTING

8
CONTINUED FROM PAGE 7
Symptom
Furnace/Air Conditioner Cycles Too Fast or
Too Slow (narrow or wide temperature swing)
Thermostat Setting and Thermostat
Thermometer Disagree
Blank Display and/or Keypad Not
Responding
Heat Setpoint Will Not Respond
to the Temperature Up Key
Cool Setpoint Will Not Respond
to the Temperature Down Key
The Emerson logo is a
trademark and a service mark
of Emerson Electric Co.
Possible Cause
1. The location of the thermostat and/or the
size of the Heating/Cooling System may be
influencing the cycle rate.
1. Thermostat thermometer setting requires
adjustment.
1. Voltage spike or static discharge.
1. The desired setpoint conflicts with the
setpoint of the COOL mode.
1. The desired setpoint conflicts with the
setpoint of the HEAT mode.
www.white-rodgers.com
Corrective Action
Digital thermostats normally provide precise
temperature control and may cycle faster than
some older mechanical models. A faster cycle
rate means the unit turns on and off more
frequently but runs for a shorter time so there is
no increase in energy use. If you would like to
increase the cycle time, refer to step 3 on the
Configuration Menu
The thermometer can be adjusted +/- 3 degrees.
See Temperature Display Adjustment in the
Operation section.
Use the Reset Operation listed above.
Change system mode to COOL. Raise the Cool
setpoint. Return to HEAT mode and set desired
temperature.
Change system mode to HEAT. Lower the Heat
setpoint. Return to COOL mode and set desired
temperature.