CHECk GAS TYPE

Use only natural gas. If your gas supply is not
natural gas, you must install ON/OFF Safety
Valve/Pilot Kit (see Accessories, page 19).
Call dealer where you bought your log set.
If the fireplace does not have a gas supply
shutoff valve, one must be installed.
VENTING SPECIFICATIONS FOR
INSTALLATION
Fireplace chimney flue and vent must be draft-
ing properly. To check vent for proper drafting:
Light a tightly rolled newspaper on one end
and place at inside front edge of fireplace.
Observe smoke and be sure vent is properly
drawing it up the chimney. If smoke spills out
into room, extinguish flame and remove any
obstruction until proper venting is achieved.
Chimney flue damper must be fixed open to
provide a minimum of 64 sq. in. of free air
opening during operation of this log set. A
multipurpose damper clamp is provided to fix
the damper in position.
6
INSTALLATION
DESCRIPTION
18" Single Burner
24" Single Burner
18" Dual Burner
24" Dual Burner
30" Dual Burner
MINIMUM FIREBOX SIZES
FRONT
MODEL
WIDTH*
18SR/DR
28"
24SR/DR
29
3
30DR
36"
* Add 6" if safety valve/pilot is used.
**At depth indicated.
BURNER ORIFICE
Natural
In.
Num.
0.120
31
0.129
30
Figure 2 - Technical Information Charts
www.desatech.com
Continued
Btu/Hr Input
Btu/Hr Input
Natural Gas
Propane/LP Gas
50,000
60,000
55,000
65,000
70,000
BACK
WIDTH**
DEPTH
16"
14"
/
"
17"
15
4
27"
18"
Propane/LP
In.
Num.
0.073
49
0.086
44
INSTALLING DAMPER CLAMP
Secure damper stop clamp provided to
leading edge of damper as shown in Figure
3. If for any reason this clamp doesn't work
on your fireplace, another suitable clamp or
permanent stop must be installed, or damper
blade must be cut or removed.
Damper
Clamp
Damper
Masonry Fireplace
Figure 3 - Attaching Damper Clamp
Minimum
vent Opening
40,000
8" dia.
50,000
8" dia.
45,000
8" dia.
55,000
8" dia.
60,000
8" dia.
HEIGHT
18"
/
"
18"
1
2
18"
FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)
Min.
NG
5.5"
LP
11"
Damper
Damper
Clamp
Manufactured Fireplace
Max.
10.5"
13"
Damper
901746-01E