Extension Cords - Chicago Welding 67102 Set Up And Operating Instructions Manual

80w plastic welding kit with iron
Table of Contents

Advertisement

2.
Grounding prong in plug is connected
through green wire inside cord to
grounding system in tool. Green wire
in cord must be only wire connected
to tool's grounding system and must
never be attached to "live" terminal.
(see 3-prong plug and outlet.)
3.
Tool must be plugged into appropriate
outlet, properly installed and
grounded in accordance with codes
and ordinances. Plug and outlet
should look like preceding illustration.
(see 3-prong plug and outlet.)

extension cords

1.
Grounded
tools require a three wire
extension cord. Double Insulated
tools can use either a two or three
wire extension cord.
2.
As distance from supply outlet
increases, use a heavier gauge
extension cord. Using extension
cords with inadequately sized wire
causes a drop in voltage, resulting
in loss of power and possible tool
damage. The smaller the gauge
number of wire, the greater capacity
of cord. For example, a 14 gauge
cord can carry a higher current than a
16 gauge cord. (see table a.)
3.
When using more than one extension
cord to make up the total length,
make sure each cord contains at
least the minimum wire size required.
(see table a.)
4.
If using extension cord for more than
one tool, add nameplate amperes
and use sum to determine required
minimum cord size. (see table a.)
5.
If using extension cord outdoors,
make sure it is marked with "W-
SKU 67102
For technical questions, please call 1-800-444-3353.
A" ("W" in Canada) to indicate it is
acceptable for outdoor use.
6.
Make sure extension cord is properly
wired and in good electrical condition.
Always replace damaged extension
cord or have it repaired by a qualified
electrician before using it.
7.
Protect extension cords from sharp
objects, high heat, and wet areas.
recoMMended MiniMuM wire
gauge For eXtension cords*
(120/240 Volt)
naMeplate
aMperes
(at full load)
0 – 2.0
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
taBle a
symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
a
Amperes
No Load Revolutions per Minute
n 0 xxxx/min.
(RPM)
eXtension cord
length
18
18
18
18
18
18
18
16
18
18
16
14
18
16
14
12
18
14
12
10
14
12
10
-
12
10
-
-
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
Page 6