Programming steps:
1. Accessing the correction mode
-
Turn the main switch off.
-
Press the "P" key and hold down.
-
Turn the main switch on.
The display shows "C-0000".
-
Release the "P" key.
2. Changing to the technician level
-
Enter code number "1907" via the numeric keys "1...0".
-
Press the "E" key.
The controls change to the "technician level".
The display shows the parameter no. "F-100".
-
When an incorrect code number is entered the text "C-0000 Info F1" appears.
Repeat the entry.
3. Programming the reference position
-
Enter parameter number "170" via the numeric keys "1...0".
-
Press the "E" key.
The display shows the parameter "F-170" with the short designation "Sr1" (Ser-
vice routine 1).
The LED above the "F" key blinks.
-
Press the "F" key.
The display shows "Position 0".
-
Turn the handwheel at least one revolution in the direction of run until the refer-
ence position is reached (needle point at needle plate level).
-
Press the "P" key.
The set reference position is stored.
4. Programming position 1
-
Enter parameter number "171" via the numeric keys "1...0".
-
Press the "E" key.
The display shows the parameter "F-171" with the short designation "Sr2" (Ser-
vice routine 2).
The LED above the "F" key blinks.
-
Press the "F" key.
The display shows "Position 1" and the corresponding number of increments.
-
Turn the handwheel until the 1st position is reached.
5. Programming position 2
-
Press the "E" key.
The display shows "Position 2" and the corresponding number of increments.
-
Turn the handwheel until the 2nd position is reached.