PROGRAMMING FUNCTIONS - (cont.)

ENABLE ADS?

This function allows the operator to choose whether
or not to display the advertising message that was en-
tered into the brewer with an AD CARD. This message
will be displayed when the brewer is not in use.
ENABLE ADS ?
NO
DONE
Procedure to Enable/Disable Ads:
1. Press and hold upper right hidden switch until the
display reads UNITS. Release switch. Continue to
press and release switch until the display reads
ENABLE ADS. The YES or NO will be flashing to
indicate the current selection.
2. Press and release the NO to disable this function
(no ads will be displayed on the screen), or;
3. Press and release the YES to enable this function
(ads will be displayed on screen).
4. When finished, press and release DONE to save
the new setting, exit the ENABLE ADS function and
advance to the next function screen, SET TEMP.
Another alternative is to press and release the
ON/OFF switch (either on DUAL brewers) located
on the front switch panel to exit the ENABLE ADS
function and return to the MAIN SCREEN.
SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C)
This function allows the operator to set the brew
water temperature in the tank. It also sets the hot
water faucet dispense temperature.
SET TEMP: XXX°
(-)
DONE
Procedure to set brew temperature:
1. Press and hold upper right hidden switch until the
display reads UNITS. Release switch. Continue to
press and release switch until the display reads
SET TEMP.
2. To adjust the brew temperature, press (-) to de-
crease or (+) to increase the brew temperature.
YES
(+)
Page 28
3. When finished, press and release DONE to save
the new setting, exit the SET TEMP function and
advance to the next function screen, SET READY.
Another alternative is to press and release the ON/
OFF switch (either on DUAL brewers) located on
the front switch panel to exit the SET TEMP func-
tion and return to the MAIN SCREEN.
NOTICE
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
Brew water temperature is factory set at 200∞ F (93.3∞ C)
Areas of high altitude will require lowering this tempera-
ture to prevent boiling. This chart should be used as a
guide when readjusting the brew water temperature.
Boiling point
Altitude
of water
∞ F
(Feet)
-1000
213.8
-500
212.9
0
212.0
500
211.1
1000
210.2
1500
209.3
2000
208.4
2500
207.4
3000
206.5
3500
205.6
4000
204.7
4500
203.8
5000
202.9
5500
201.9
6000
201.0
6500
200.1
7000
199.2
7500
198.3
8000
197.4
8500
196.5
9000
195.5
9500
194.6
10000
193.7
35665.0000A 05/04 © 2004 Bunn-O-Matic Corporation
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The
range can be from 185˚F (85˚C) to within 2˚F (-1.7°C)
of the SET TEMP. The water must be at the SET READY
temperature or higher for the display to indicate READY
TO BREW. If brew lockout is enabled, the brewing pro-
cess will not start below this READY temperature.
NOTE: The upper limit for SET READY temperature
is 2˚F (-1.7°C) less than the water temperature (SET
TEMP) setting.
SET READY: XXX°
(-)
DONE
Recommended
water temperature
∞ C
∞ F
∞ C
101.0
200
93.3
100.5
200
93.3
100.0
200
93.3
99.5
200
93.3
99.0
200
93.3
98.5
200
93.3
98.0
200
93.3
97.4
200
93.3
96.9
199
92.8
96.4
198
92.2
95.9
197
91.7
95.4
196
91.1
94.9
195
90.6
94.4
195
90.6
93.9
194
90.0
93.4
193
89.4
92.9
192
88.9
92.4
191
88.3
91.9
190
87.8
91.4
189
87.2
90.8
188
86.7
90.3
187
86.1
89.8
186
85.6
(+)
41343 080108