Wiring Diagram - Bryant 350MAV Service And Maintenance Procedures Manual

4-way multipoise fixed-capacity direct-vent condensing gas furnace series g
Table of Contents

Advertisement

BLOWER OFF DELAY
PCB
JUMPER SELECT
Y1
90
DHUM
120
G
150
C
om
24V
180
BLU
W
J1
Y/Y2
TEST/TWIN
ORN
R
HUM
FU1
NOTE #6
WHT
SEC-2
SEC-1
LED 1
RED
WHT
EAC-2
L2
RED
GRN/YEL
GRN/YEL
WHT
PL1
PL2
BHT/CLR
BFANR
BLWR
2
COOL
L1
FAN
HEAT
SPARE 1
EAC-1
SPARE 2
PR1
BLK (HI)
WHT
(COM)
BLWM
GRN/YEL
YEL
(MED HI)
BRN
OL
START
CAP -1
NOTE #10
RED (LO)
BLU
BRN
(MED LO)
BFANR
CONTINUOUS-FAN SELECT RELAY, SPDT
L
BHT/CLR
BLOWER MOTOR SPEED CHANGE RELAY, SPDT
E
BLWR
BLOWER MOTOR RELAY, SPST-(N.O.)
G
BLWM
BLOWER MOTOR, PERMANENT-SPLIT-CAPACITOR
CAP 1, 2
CAPACITOR
E
CPU
MICROPROCESSOR AND CIRCUITRY
N
EAC-1
ELECTRONIC AIR CLEANER CONNECTION (115 VAC 1.0 AMP MAX.)
D
EAC-2
ELECTRONIC AIR CLEANER CONNECTION (COMMON)
FRS
FLAME ROLLOUT SW. -MANUAL RESET, SPST-(N.C.)
FSE
FLAME-PROVING ELECTRODE
FU 1
FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED
FU 2
FUSE OR CIRCUIT BREAKER CURRENT INTERRUPT DEVICE
(FIELD INSTALLED & SUPPLIED)
GND
EQUIPMENT GROUND
GV
GAS VALVE-REDUNDANT
GVR 1, 2
GAS VALVE RELAY, DPST-(N.O.)
HSI
HOT SURFACE IGNITER (115 VAC)
HSIR
HOT SURFACE IGNITER RELAY, SPST-(N.O.)
HUM
24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)
IDM
INDUCED DRAFT MOTOR, PSC
IDR
INDUCED DRAFT MOTOR RELAY, SPST-(N.O.)
ILK
BLOWER ACCESS PANEL INTERLOCK SWITCH, SPST-(N.O.)
J1
BLOWER - OFF DELAY JUMPER SELECTOR
JB
JUNCTION BOX
LED
LIGHT-EMITTING DIODE FOR STATUS CODES - AMBER
LGPS
LOW GAS PRESSURE SWITCH, SPST-(N.O.)
LS
LIMIT SWITCH, AUTO-RESET, SPST (N.C.)
(WHEN USED)
LGPS
PRS
ORN
NOTE #11
BLU
RED
RED
LS
FRS
RED
GRN/YEL
BLU
RED
WHT
BRN
PL4
YEL
WHT
3
FSE
GRN/YEL
2
1
BLK
1
PL3
WHT
2
BLK
BLK
1
BLK
WHT (COM)
WHT
BLK
FUSED OR CIRCUIT BREAKER
DISCONNECT SWITCH (WHEN REQ'D)
JB
WHT
WHT
BLK
BLK
ILK
GND
OL
AUTO-RESET INTERNAL MOTOR OVERLOAD
TEMPERATURE SWITCH (N.C.)
PCB
PRINTED CIRCUIT BOARD CONTROL
PL1
11-CIRCUIT PCB CONNECTOR
PL2
2-CIRCUIT CONNECTOR
PL3
2-CIRCUIT HSI, CONNECTOR
PL4
3-CIRCUIT IDM EXTENSION CONNECTOR
PRS
PRESSURE SWITCH, SPST-(N.O.)
TEST/TWIN
COMPONENT TEST & TWIN TERMINAL
TRAN
TRANSFORMER-115VAC/24VAC
JUNCTION
UNMARKED TERMINAL
PCB CONTROL TERMINAL
FACTORY WIRING (115VAC)
FACTORY WIRING (24VAC)
FIELD WIRING (115VAC)
FIELD WIRING (24VAC)
CONDUCTOR ON CONTROL PCB
FIELD WIRING SCREW TERMINAL
FIELD EARTH GROUND
EQUIPMENT GROUND
FIELD SPLICE
PLUG RECEPTACLE
Fig. 16—Wiring Diagram
TO 115VAC FIELD DISCONNECT
NOTE #2
L2
L1
GND
ILK
YEL
L1
FAN
GV
BLWR
M
C
EAC-1
GRN/YEL
HSIR
NOTE #3
IDR
PL2
BLK
PR1
115VAC
WHT
TRAN
CAP -2
24VAC
TEST/TWIN
BRN
M
NOTE #6
AUX
F U 1
IDM
OL
SEC-1
WHT
GVR-2
HUM
R
W
NOTE #2
NEUTRAL
FU2
Y/Y2
L1
CPU
DHUM
Y1
G
C
OM
PCB
NOTE #5
NOTES:
1. If any of the original equipment wire is replaced use wire rated for 105 C.
2. Use only copper wire between the disconnect switch and the furnace junction box (JB).
3. This wire must be connected to furnace sheet metal for control to prove flame.
4. Symbols are electrical representation only.
5. Solid lines inside PCB are printed circuit board conductors and are not included in legend.
6. Replace only with a 3 amp fuse.
7. Inducer (IDM) and blower (BLWM) motors contain internal auto-reset thermal overload switches (OL).
8. Neutral connections are interchangeable within the NEUTRAL connector block.
9. Blower motor speed selections are for average conditions, see installation instructions for details on
optimum speed selection.
10. YELLOW lead not on all motors.
11. Factory connected when LGPS is not used.
12. Ignition-lockout will occur after four consecutive unsuccessful trials-for-ignition. Control will
auto-reset after three hours.
13. Blower-on delay: gas heating 60 seconds, cooling or heat pump 2 seconds.
14. Blower-off delay: gas heating selections are 90, 120, 150 or 180 seconds, cooling or heat pump
90 seconds or 5 seconds when dehumidify call is active.
SCHEMATIC DIAGRAM
(NATURAL GAS & PROPANE)
EQUIPMENT GROUND
LO
CAP-1
FAN
MED LO
HEAT
MED HI
HI
START
SPARE-1
NOTE #10
OL
HI/LO
COOL
EAC-2
BLWM
COM
1
HSI
1
IDM
2
2
PL3
OL
M
AUX
1
3
PL4
CAP - 2
2
SEC-2
FRS
6
8
LGPS
(WHEN USED)
2
PL1
NOTE #11
PRS
4
GV
GVR-1
10
M
C
5
NOTE #3
1
9
FSE
7
3
11
326796-101 REV. A
A02157
L2
LS