Phantom Power For Mic 5 & Mic 6; Remote Volume Control; Precedence Connections - Bogen Gold Seal GS100 Installation And Use Manual

Gold seal series amplifier
Hide thumbs Also See for Gold Seal GS100:
Table of Contents

Advertisement

Input Connections
Removal of the amplifier cover exposes internal components and presents an electrical shock hazard. For this
reason, do not perform any functions requiring removal of the cover of the amplifier unless you are qualified
to do so. Always disconnect AC power from the unit before attempting to remove the cover.
Phantom Power for MIC 5 & MIC 6
A single internal jumper is provided to supply phantom power to both MIC 5 and MIC 6. The amplifier is shipped with
the jumper in the OFF position. Place Jumper across "ON" Pins to apply Phantom Power to both MIC 5 and MIC 6.
See the figure below for the location of the phantom power jumper.

Remote Volume Control

If remote volume control is desired, connect the Bogen acces-
sory GSRVC Remote Volume Control to the screw terminals
marked REMOTE MSTR. Wire length can be up to 1000 feet
using 22-gauge wire. Connections are not polarity sensitive.

Precedence Connections

Precedence connections allow any combination of inputs to
be completely muted with a contact closure. Closing a contact
across any of the precedence terminals and the PREC COM
1 terminal will mute that input. A customer-supplied normally-
open SPST switch, push-to-talk switch, microphone switch,
relay or telephone system contact can be used to provide the
closure.
Note: Activating the precedence control for AUX
inputs completely mutes the input signal. The
VAR MUTE control has no effect when muting
inputs using precedence control.
WARNING
(Inside Unit)
MIC 5 and MIC 6 input terminal strip
Phantom Power Jumper Location
for MIC 5 and MIC 6
(Rear Panel; #10)
(Rear Panel; #11)
10