Behringer FEEDBACK DESTROYER PRO FBQ2496 User Manual page 9

Automatic and ultra-fast feedback destroyer/parametric eq with 40 fbq filters and 96 khz audio performance
Hide thumbs Also See for FEEDBACK DESTROYER PRO FBQ2496:
Table of Contents

Advertisement

9
FEEDBACK DESTROYER PRO FBQ2496 User Manual
4.2 Setting up parametric filters
Some or even all 40 filters on your FBQ2496 can be deployed as parametric filters.
They have to be set up in a targeted fashion, with great precision. The frequency,
bandwidth and gain parameters are available.
Selecting the number of parametric filters
1. Keep the PEQ button pressed for a few moments. The LED on the PEQ button
blinks, and the display shows the current number of parametric filters (p 0 =
no parametric filters deployed, P20 = all filters are parametric). Additionally,
the LEDs on the deployed Single-Shot filters are lit.
2. You can use the wheel to change the number of parametric filters.
The display shows the number of deployed parametric filters, and the
corresponding LEDs in the status display ( (8) ) are lit.
3. Pressing the PEQ button again briefly completes the procedure.
Now, the only parametric filters whose LEDs are still lit are those
whose gain (either positive or negative) does not equal zero.
Setting up frequency, bandwidth, gain
You should implement the following procedure with each individual
parametric filter:
1. Briefly press the PEQ button.
The LED on the PEQ button is lit. The display indicates the number of the
selected filter (e.g. 19).
2. Use the wheel to select the parametric filter whose values you wish
to modify.
Any filter may be selected using the wheel! However, the parameters of
the Single-Shot and automatic filters can only be displays and can not
be modified!
3. After you press the FREQUENCY button, use the wheel to set the filter mid
frequency (the LED on the button blinks).
You can get a precise readout of the set mid frequency by observing the
display and the status of the Hz/kHz LED next to it.
To modify exactly the frequency band you have in mind, you can shift the
filter
s bandwidth.
'
4. Briefly press the BANDWIDTH button.
5. Turning the wheel changes the filter
a value lower than 0.1 is set ( 1 x 1/60, 2 x 1/60 ... 5 x 1/60). In case of larger
bandwidths, the value is shown directly in the display (0.1, 0.2 ... 1.0,
1.1 ... 10.0).
A parametric filter becomes engaged only after an increase/decrease of the set
frequency is entered:
6. Briefly press the GAIN button. The LED on the button is lit. At the same time,
the dB LED under the 3-digit display is also lit.
s bandwidth. The 1/60 LED lights up if
'
7. The gain can be adjusted using the wheel. The available values range from
15 dB to - 36 dB (can be changed in 0.5-dB increments in the +15 dB to
-15 dB range; in 1-dB increments in the -16 to -36 dB range). The value is
shown in the display.
The FBQ2496 has a 3-digit display. Positive values are easily represented
( 1 4, 14.5, 15). For negative values, complete representation would
require 4 digits. However, because the display only shows 3 digits,
the position after the decimal point is omitted and replaced by a
dot to the right of the first two digits (-15, -14.(5), -14, -13.(5)),
which stands for the missing decimal value.
8. Press the PEQ button briefly again to complete the procedure.
The status display only shows the filters whose gain does not equal to
zero (either positive or negative).
4.3 Setting up automatic filters
The number of automatic filters can not be separately set. It results from the
number of fixed and parametric filters (fig. 4.2).
To lower the number of automatic filters, increase the number of
Single-Shot and/or parametric filters.
The automatic filters automatically spring into action on a per-need basis during
a performance or a recording session. Of course, having the FBQ2496 react to
changing situations would be desirable. To allow for this, you need to establish
a setup in which the automatic filters are only periodically active, setting
themselves back to zero afterwards in order to be ready for the next instance in
which feedback is occurring.
The so-called "Filter Lifting Time" informs you about how long a filter set to
automatic may remain active before its values are reset back to zero. This Filter
Lifting Time can be set on the FBQ2496.
1. Press the FILTER LIFT button. The LED on the button starts to blink.
2. Using the wheel, Filter Lifting Time can either be turned off (off) or can be
set to 1 min, 5 min, 10 min, 30 min or 60 min.
3. To exit this menu, press the FILTER LIFT button again. The LED no
longer blinks.
4. If a Filter Lifting Time value has been set (i.e. any value other than off!),
the button LED is lit.
If a satisfactory setting for the Single-Shot and automatic filters
has been achieved, you can keep this setting by pressing the FREEZE
button. The display shows: -.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents