SkyLink DM-100 User Instructions page 16

Swing door opener
Hide thumbs Also See for DM-100:
Table of Contents

Advertisement

INSTALLATION - IN SWING
Armature plate
Soft Spacer
1
8.2 Secure the armature plate mounting
bracket and spacer on the upper corner
of the top door jamb with the armature
screw, eyelet and a washer.
Note: Pay attention to the armature plate,
it can only be mounted properly with the
correct side facing up.
Even if screw is tightened all the way, you
may find the armature plate is a bit loose,
which is normal.
8.3
1). Secure the screws between the "L-shape" bracket
and the electromagnetic lock.
2). Secure the 2 screws between the upper and lower
"L-shape" brackets. Do not tighten these screws
too much because the position may still need to be
adjusted.
3). Position the lock assembly so that the lock is directly
on top of the armature plate. Tighten the 4 screws
from the lower "L-shape" bracket to the door.
4). Move the lock towards the armature plate by sliding it
forward and ensure they are contacting each other.
You can now tighten the 2 screws between the upper
and lower brackets.
8.4
The 2 wires from the lock should be connected to the "T1"
terminals (the most upper left terminal) on the operator.
Polarity does not matter.
1
3
2
Don't tighten
4
Tighten
Mounting Bracket
Actual size
1
1
x1
x1
1
1
x1
x1
1
Actual size
1
x1
1
x1
2 3
x6
3
x4
15
8.5 After mounting the lock on the door, you can now mount the armature plate on the door jamb. (Follow Fig. A to
mount the armature plate. If the door jamb width is less than 3" (75mm), follow Fig.B)
1) Secure the armature plate to the "L-shape" bracket with a screw and an eyelet. Note: Pay attention to the
armature plate, it can only be mounted properly with the correct side facing up. Even if the screw is
tightened all the way, you may find the armature plate is a bit loose, which is normal.
2) Position the armature plate assembly so that the armature plate is directly on top of the lock. Tighten the
4 screws from the "L-shape" bracket to the door jamb with washers and spring washers.
8.6 The 2 wires from the lock should be connected to the "T1" terminals on the operator. Polarity does not matter.
2
1
Eyelet
x1
2
x4
1
Fig.A
x1
2
x2
2 3
x6
Fig.B
INSTALLATION - OUT SWING
Door jamb width: More than 3" (75mm)
1
Soft
Armature
Eyelet
spacer
plate
2
Door jamb width: Less than 3" (75mm)
1
Soft
Armature
Eyelet
spacer
plate
2
24
Actual size
1
x1
1
x1
1
x1
3 2
x4
3 1
2
x5
3 1
2
x5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dm-50

Table of Contents