Download Print this page

Installation Guide; User Guide - Danfoss RAS-D2 Combi Instruction

Radiator thermostat

Advertisement

Installation Guide

Fitting the Sensor
1. Remove cap
from valve and
turn sensor to
2. Press the sensor
firmly onto the valve.
Sensor horizontal:
ensuring that the
scale pointer is
at top.
Sensor vertical:
ensuring that
the scale pointer is
at the front.
3. Whilst holding the
sensor firmly on the
valve secure
connection by tightening
the Allen screw using the
enclosed key.
4. Set desired room temperature.
Removing the Sensor
Loosen the Allen screw (3).
The sensor can now be separated from the valve.

User Guide

Setting the desired room temperatures
The desired room temperature is set by turning
the head. The temperatures obtained are ap-
proximately:
Do not cover the thermostat
The thermostat opens and closes as determined
by the temperature around it. Therefore the sen-
sor must never be hidden behind thick curtains,
furniture, etc. Alternatively a thermostat with
remote sensor should be used.
Positive SHUT-OFF feature:
The head can be turned past the
slight resistance will be felt) to setting "0" at which
point the water flow is shut off completely. After
also shutting the lockshield valve the radiator may
be drained and removed for maintenance and
decoration purposes.
Lockshield valve RLV-D is included
in codes: Code no's 013G6016 and 013G6017
Removal of
protective cap
This package contains
Sensor Chrome: 013G6170 or - Chrome/RAL 9016: 013G6176
and valve RA-FS - Chrome: 013G6282
setting (a
Balancing

Advertisement

loading