421D
Users Manual
Press this button (short press) to take the next
measurement from the front edge
After a measurement the reference returns automatically
to the default setting (rear reference). See figure {H}.
H
1
Measure
Min Max
2
Press this button (long press) to set the reference to
the front. Does not return to default (rear) reference.
Press this button, the rear reference is set again.
14
.
Measuring
Single distance measurement
Press to activate the laser. Press again to trigger
the distance measurement.
The result is displayed immediately.
Minimum/maximum measurement
This function allows the user to measure the minimum or
maximum distance from a fixed measuring point. It can
also be used as to determine spacings. See figure {I}.
I
Min.
It is commonly used to measure room diagonals
(maximum values) or horizontal distances (minimum
values).
Press and hold down this button until you hear a
beep. Then slowly sweep the laser back and forth and up
and down over the desired target point - (for example,
into the corner of a room).
Max.