Door Reversal; Electrical Connection - Electrolux U30428 EUFG29800 Instruction Book

Electrolux freezer instruction book
Table of Contents

Advertisement

·
there is good air circulation around
the cabinet and that the air channels
below and behind the cabinet are not
blocked. The ventilation space above
the cabinet must be at least 4 cm.
The ventilation space can either be
a) directly above the cabinet, or
b) behind and above the top cupboard.
In this case, the space behind the
cupboard must be at least 50 mm deep.
a)
Cabinet is placed at a location where
the ambient temperature corresponds
to the climate classification*, for which
the appliance is designed.
* See on the rating plate on the inside
of the appliance.
The following table shows which
ambient temperature is correct for
each climate classification.
Climate
classifi-
cation
SN
+10°C to +32°C
N
+16°C to +32°C
+18°C to +38°C
ST
T
+18°C to +43°C
If the cabinet is placed in a corner and
the side with the hinges facing the
wall, the distance between the wall
and the cabinet must be at least 15
b)
50mm
for an ambient
temperature of
mm to allow the door to open enough
so that the baskets can be removed.
The power plug must be accessible
after installation of the cabinet.

Door Reversal

Important
If necessary for your installation, the
door hinge may only be adapted by
an authorised plumbing technician. If
you need to re-hang the door,
contact your local Electrolux service
centre.

Electrical connection

This appliance must be earthed.
If the plug that is fitted to your
appliance is not suitable for your
socket outlett, it must be cut of and
the appropriate plug fitted.
Remove the fuse from the cut off
plug.The cut off plug should then be
disposed of to prevent the hazard of
socket inanother part of your home.
The wires in the mains lead are
coloured in accordance with the
following code:
Green and yellow
Blue
Brown
If you fit your own plug, the colours of
the Wires in the mains lead of your
appliance may not correspond with
the markings identifying the terminals
in your plug, proceed as follows:
!
-Earth
-Neutral
-Live
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eufg29800

Table of Contents