Opening Should Have A Minimum Free Area Of 1 Square; /Kw) Of Total Input - American Water Heater POWER VENT GAS Installation And Operating Manual

Power vent gas hybrid gas water heaters
Table of Contents

Advertisement

B. ALL AIR FROM OUTDOORS: (See Figures 12, 13 and
14)
openings, one commencing within 12 in. (30cm) of the top
and one commencing within 12 in. (30cm) from the bottom
of the enclosure. The openings should communicate
directly, or by ducts, with the outdoors or spaces (crawl or
attic) that freely communicate with the outdoors.
1. When directly communicating with the outdoors, each
inch per 4,000 Btu per hour (5.5 cm
rating of all equipment in the enclosure (see Figure
12).
2. When communicating with the outdoors through vertical
ducts, each opening should have a minimum free area
of 1 square inch per 4,000 Btu per hour (5.5 cm
of total input rating of all equipment in the enclosure
(see Figure 13).
3. When communicating with the outdoors through
horizontal ducts, each opening should have a minimum
free area of 1 square inch per 2,000 Btu per hour (11
cm
2
/kW)) of total input rating of all equipment in the
enclosure (see Figure 14).
4. When ducts are used, they should be of the same
2
5. Alternatively a single permanent opening may be used
2
/kW)
FIGURE 13
cross-sectional area as the free area of the openings to
which they connect. The minimum short side dimension
of rectangular air ducts should not be less than 3 in.
(7.6cm) (see Figure 14).
when communicating directly with the outdoors, or with
spaces that freely communicate with the outdoors. The

opening should have a minimum free area of 1 square

inch per 3,000 BTU per hour (8.3 cm
rating of all equipment in enclosure (see Figure 15).
FIGURE 15
2

/kW) of total input

17