LC-40/46/52/60LE810UN (1st Edition)
When C-S FPC(2 pieces) is replaced, does screen display normally?
NO
When C-PWB is replaced, does screen display normally?
NO
Replace Panel HIRAKI.
(Adjust "VCOM ADJ" after replace Panel HIRAKI)
[2] LED flashing specification at the time of an error (Center icon LED used)
1. Display method
•
Since only the center icon LED can be used, slow flashing and fast flashing are combined.
•
Refer to Table 1.
•
The Start from the detail display. (No outline display)
•
After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the process screen.
•
During version upgrade, the brightness of the flashing LED changes smoothly.
•
When completing version upgrade, the brightness of the LED changes in a staircase pattern.
2. LED flashing method
Error flashing
<Detail display example>
Center icon
400ms
400ms
•
Flashing during Verup
Center icon
500ms
500ms
•
Flashing when completing Verup
Center icon
1000ms
1000ms
Trouble Shooting Panel Module
Replace C-S FPC(2 pieces).
Replace C-PWB.
(Adjust "VCOM ADJ" after replace C-PWB)
1600ms
300ms
100ms
1000ms
1000ms
YES
YES
1600ms
ON
OFF
ON
OFF
6 – 14
ON
OFF