Brother KE-430F Instruction Manual page 33

Electronic direct drive lockstitch bar tacker electronic direct drive lockstitch button sewer
Hide thumbs Also See for KE-430F:
Table of Contents

Advertisement

Operator
4145M
2348B
Green and yellow wire
(ground wire)
2351B
KE-430F, BE-438F
3. INSTALLATION
<100 V / 400 V system >
(1) Power switch
(2) Screws [2 pcs]
(3) Transformer box
(4) Transformer box plates [2 pcs]
(5) Screw [with washer]
(6) 3-pin power supply connector
(7) Staples [6 pcs]
(8) Cord clamps [2 pcs]
(9) Power cord
1. Attach an appropriate plug to the
power cord (9). (The green and yellow
wire is the ground wire.)
2. Insert
the
power
properly-grounded AC power supply.
* The inside of the control box uses
single-phase power.
NOTE:
• If the ground connection is not secure,
electric shocks, operating errors or
damage to electronic components such
as P.C. boards may occur.
• Take care when tapping in the staples
(7) to make sure that they do not pierce
the cords.
• Do not use extension cords, otherwise
machine
operation
problems
result.
3. Use the six screws to tighten the cover
of the control box. Check that none of
the cords are being clamped by the
cover at this time.