2 Installing and configuring HP 16Gb FC Switches

This chapter provides installation and configuration information for the HP 16Gb FC Switches.

Accessories

The following items are included with the standard shipment of a fully-configured HP 16Gb FC
Switch. When opening the packages, verify that the following items are included and that no
damage has occurred during shipping:
One HP SN6000B 16Gb FC Switch with two integrated power supply/fan assemblies, or
one HP SN3000B 16Gb FC Switch with one integrated power supply/fan assembly
NOTE:
power supply/fan assembly, which must be ordered separately.
Serial cable with an RJ-45 connector plus an adaptor for RJ-45 to DB9
Power cords: two included with the SN6000B, one included with the SN3000B
Rubber feet, required to set up the switch as a standalone unit
One accessory kit with the following items:
Rack Mount Kit, including rails, rail mounting hardware, and plenum
HP product documentation, including Read Me First, Safety Guides, User License, and
Warranty
Brocade EZ Switch and China ROHS documentation
HP SAN Network Advisor DVD

Installation and safety considerations

You can install the switch in a rack or as a standalone device on a flat surface. HP highly
recommends mounting the switch in an HP 10000 Series Rack.

Electrical considerations

For successful installation and operation of the switch, ensure that the following electrical
requirements are met:
The primary outlet is wired correctly, protected by a circuit breaker, and grounded in
accordance with local electrical codes.
The supply circuit, line fusing, and wire size are adequate, as specified by the electrical rating
on the switch nameplate.
A maximum of 71.36 cubic meters/hour (42 cubic feet/minute). Nominal airflow is 59.47
cubic meters/hour (35 cubic feet/minute).
The primary AC input is 85–264 VAC Nominal: 100–240 VAC, 2.0 A; 47–63 Hz. The switch
autosenses input voltage.

Environmental considerations

For successful installation and operation of the switch, ensure that the following environmental
requirements are met: