A.3.8 MFGPAGE Command
Command Line
Program Return Value
A.3.9 CONSTCHK Command
Command Line
Program Return Value
A.3.10 ACTIVATE Command
Command Line
Program Return Value
Page 40
The MFGPAGE command updates information on manufacturing pages. Only DOS and
EFI support this command.
sas2ircu
<offset> <value>
<controller_#> – The index of the controller with the manufacturing pages
Parameters
you want to update.
<passcode> – The passcode required for DOS access.
<mfgpage_#> – The manufacturing page (4 or 10) that requires an update.
<offset> – The DWord offset of the specified manufacturing page that requires
an update, in hexadecimal format.
<value> – The value for the offset to be modified, in hexadecimal format.
0x00
SUCCESS: Command completed successfully.
0x01
FAILURE: Bad command-line arguments or operational failure.
0x02
ADAPTER_NOT_FOUND: Cannot find specified adapter.
The CONSTCHK command sends requests to the Integrated RAID firmware to start a
consistency check operation on the specified volume.
sas2ircu <controller_#> constchk <volumeId> [noprompt]
<controller_#> – The index of the controller on which the consistency check
Parameters
operation will run.
<volumeId> – The volume ID of an Integrated RAID volume, as listed in the
DISPLAY command, on which the consistency check operation will run.
noprompt – This optional parameter prevents warnings and prompts from
appearing while the command is running.
0x00
SUCCESS: Command completed successfully.
0x01
FAILURE: Bad command-line arguments or operational failure.
0x02
ADAPTER_NOT_FOUND: Cannot find specified adapter.
The ACTIVATE command activates an inactive Integrated RAID volume.
sas2ircu
<controller_#> – The index of the controller with the volume that requires
Parameters
activation.
<volumeId> – The volume ID of an Integrated RAID volume currently in the
Inactive state.
0x00
SUCCESS: Command completed successfully.
0x01
FAILURE: Bad command-line arguments or operational failure.
0x02
ADAPTER_NOT_FOUND: Cannot find specified adapter.
<controller_#> mfgpage <passcode> <mfgpage_#>
<controller_#>
activate <volumeId>
SAS2 Integrated RAID Solution User Guide
|