Step 7: Press C or CTRL-H when indicated to enter the utility. When the home screen appears, the new
disk will be marked as "Unconfigured bad" and the missing disk will be labeled in red. Click on the new
unconfigured disk in order to configure it and add it to the RAID array.
Figure 14
LSI WebBIOS – Unconfigured bad disk
Step 8: From the next screen, select the option to make the disk "Unconfigured good" so it can be made
to be part of a disk group and click "Go." The next screen will display the configured disk groups. The
group from which the original disk was missing will be indicated. Select the location of the disk from the
row labeled "DG Missing Row," where the listed options will be the locations where a disk was missing
from the RAID array. The radio button marked "Replace Missing PD" will be checked. Click "Go" to
complete the operation.
Figure 15
LSI WebBIOS – Replacing a physical disk