LG LW1013CR Owner's Manual page 14

9,500 btu casement air conditioner with remote
Hide thumbs Also See for LW1013CR:
Table of Contents

Advertisement

Available languages

Available languages

9. Cut side Guide seal into 2 equal lengths .
Remove protective backing and apply it to the
rear side of cabinet Side Guides , starting just
below Curtain Frame assembly. Pinch off
excess length so seal is even with the bottom
of side Guide. (Fig. 7)
10. Place Air Conditioner in window opening. It
should sit on Bracket assembly so that
Curtain Frame and cabinet Side Guides are
against top and side window jambs. Mate
front of Bracket with Base Guide attached to
the bottom of base pan.
11. Drill 3.2mm holes in window track through
the existing holes on Base Guide. Screw 4
Type C screws through the holes. (Fig. 8)
12. If this is a casement windo w installation,
proceed to Casement Window Installation. If
not, slide inner window sash firmly against
side of the cabinet.
13. Drill 3.2mm hole in window jamb to align
with the existing holes in the Cur tain Frame.
Attach Curtain Frame to window frame with
2 Type B screws. (Fig. 8)
Check all seals and plug an y
NOTICE
remaining air gaps with a suitab le
weatherproof caulk.
14. If this is a casement windo w installation,
proceed to Casement Window Installation.
If not, stuff the Foam Seal Strip between the
vertical sash and the window glass. (Fig. 9)
15. Attach the L Bracket with a Type B screw.
(Fig. 9)
Base pan
Base pan
Bracket
Bracket
Base Guide
Base Guide
Window Track
Windo
Type C screw
Window Track
Window
locking
bracket
Installation
Apply weather seal
to side guides
just below edge of
Curtain Frame .
Fig. 7
C
Type B screw
Type B screw
Fig. 8
Foam seal strip
C
Fig. 9
Owner's Manual 14